Download Print this page

BFT ELBA Installation And User Manual page 8

Hide thumbs Also See for ELBA:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
Téléchargé sur www.confort-electrique.fr
ENGLISH
Thank you for buying this product, our company is sure that you will be more
than satisied with the performance of the product.
Read the "Instruction Manual" supplied with this product carefully, as it
provides important information about safety, installation, operation and
maintenance. This product complies with recognised technical standards
and safety regulations. We declare that this product is in conformity with
the following European Directives: 2004/108/EEC (amended by RL 91/263/
EEC, 92/31/EEC and 93/68/EEC), 2006/95/EEC, 99/5/EEC.
1) GENERAL OUTLINE
Elba is a control unit for motors having maximum power of 470 W (e.g.
tubular motors for roller shutters and sunshades, roll-up door openers etc.),
compatible with the EElink protocol.
It is provided with the connections for opening (or start), closing and stop
control buttons, for accessories such as the twilight sensor, anemometer
and, when requested, safety devices.
When the key is pressed, a START command is generated.
The commands can also be sent via radio through; the transmitters can
directly be memorised by means of the key and the LED present on the
board or by means of the radio self-learning method or using the cloning
mechanism.
If the control unit allows it, set up a centralised control system via wire,
which can be divided into 8 or more zones, without having to interfere with
the wiring.
2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product can
cause damage to persons, animals or things.
The "Warnings" lealet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
speciied in the present documentation. Any other use not speciied in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and speciied in the present documentation.
Do not install the product in explosive atmosphere.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives: 2004/108/EEC, 2006/95/EEC, 98/37/ECC and
subsequent amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if itted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3 mm.
Check that a differential switch with a 0.03A threshold is itted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturers' components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualiied personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
• This application is not meant for use by people (children included) with
impaired mental, physical or sensory capacities, or people who do not have
suitable knowledge, unless they are supervised or have been instructed
by people who are responsible for their safety.
8 -
ELBA
Téléchargé sur www.confort-electrique.fr
Retrouvez tous les produits du fabricant BFT sur notre site internet www.confort-electrique.fr
INSTALLATION MANUAL
3) TECHINCAL SPECIFICATIONS
Mains power supply: ....................................................230V
Motor current: .......................................................................................... 2A
Motor power:....................................................................................... 470W
Number of storable radio-controls: ...........................................................63
Reception frequency:................................................................. 433.92MHz
Current for external attachments: ....................................................... 70mA
Maximum Number of zones with wire control (master):: ..................8 o 127
Max. connection length:.......................................................................250m
Weight: ....................................................................................
(* other voltages available on request).
4) WIRING
WARNING! For connection to the mains, use a multipolar cable having
a minimum cross section of 3x1.5 mm
standards. (For example, if the cable is not protected, it must be at least
equal to H07 RN-F, whereas if it is protected it must be at least equal
to H07 VV-F with a 3x1.5 sq mm
WARNING: Wiring must be carried out by qualiied, expert personnel in
a professional manner and in accordance with all regulations in force,
using appropriate materials.
A disconnecting switch must be installed upline from the system with a contact
separation of at least 3 mm and offering a thermal-magnetic and differential
protection capacity that is adequate for the equipment's power demand. For
wiring, use only cables that meet harmonized or national standards and
have a cross-section coordinated with the safety devices upline, with the
equipment's power demand and with installation conditions.
When running cables to the motor assembly for connection of accessories,
safety devices and controlgear, keep mains power wiring well separated
from low-voltage accessory wiring. To ensure there are no breaks in the
earth circuit, connect the actuator's earth wire to the earth wire of the
power supply using the relevant terminal provided.
Serial line connections to produce a hardwired centralized control system
must be made using only twisted pair cabling of the kind used for telephone
systems. When using a telephone cable with more than one pair, it is essential
to use wires from the same pair.
The length of the telephone cable between one unit and the next must
not be greater than 250 m.
Control buttons must have markings to show the actual direction of movement.
In the event you are connecting devices to the STOP and PHOTOCELL
terminals, you will need to remove the factory-connected jumpers. If
several devices are to be connected to one of these inputs, they must
be connected in series with each other.
TERMINAL
1-2
3-4-5
6-7
6-8
6-9
6-10
6-11
12-13
14-15
5) ADJUSTING PARAMETERS AND OPERATING LOGIC
5.1) ADJUSTING OPERATING TIME AND AUTOMATIC CLOSING TIME
TW trimmer (ig. 1): operating time adjustable from a minimum of 10 sec. to
a maximum of 240 sec..
TCA trimmer (ig. 1): automatic closing time adjustable from a minimum of 3
sec. to a maximum of 180 sec..
Retrouvez tous les produits du fabricant BFT sur notre site internet www.confort-electrique.fr
2
and complying with the current
2
cross section).
DESCRIPTION
Single-phase mains power (1=N, 2=L)
Motor connection:
3 start 1 + capacitor
4 common
5 start 2 + capacitor
OPEN/START INPUT (N.O.)
CLOSE INPUT (N.O.)
STOP/WIND SENSOR INPUT
A STOP control can be connected to this input, or a wind
sensor can be connected to provide automatic closing when
wind speed reaches a settable threshold. The setting is
made by adjusting DIP switches n° 1 and 2.
PHOT INPUT (N.C.)
The safety device operates locally only.
TWILIGHT SWITCH INPUT (N.O.)
A twilight switch can be connected to this input to provide automatic
opening and closing as environmental light conditions change.
When the contact closes, a close command is sent to the actuator;
when the contact opens again, the actuator is made to open.
24V~ max. 70mA output - power supply to photocells or
other devices.
Antenna input for built-in radio-receiver board
(14: SIGNAL. 15: BRAIDING)
±10%,
50Hz*
~
350
g approx

Advertisement

loading