Under Filter settings, the parameter for
the filter cycle are defined. Status,
duration and pump speed can be set. The
status is either "On" (√) or "Off". The filter
duration is set in hours with a maximum of
24 hours. The speed is specified in levels
with 3 various levels to choose from.
(These displays apply for the operation
mode: Interval-automatic)
One of the following controls/ messages
can be set in the Settings relay z1-z2
menu:
Release
Heating control
A selection can be made for the enable
between:
Drain
Backwash
Rinse
Filter
This provides information for the external
filter control when the valve has lowered
again and the pump can start to run. The
corresponding limits for the heating
control must be entered accordingly.
The parameters (delay time, safety time)
of the level control can be changed for the
output contact in the Settings relay 11-14
menu.
Description
EN 15