Screw Terminal (8) Null-Modem Cables (Rs-232); Screw Terminal (8) Null-Modem Cables (Rs-422) - Comtrol DeviceMaster DM-2000 Series Installation And Configuration Manual

Table of Contents

Advertisement

Connecting Serial Devices

Screw Terminal (8) Null-Modem Cables (RS-232)

An RS-232 null-modem cable is required for connecting DTE devices.

Screw Terminal (8) Null-Modem Cables (RS-422)

An RS-422 null-modem cable is required for connecting DTE devices.
98 - Connecting Serial Devices
RS-232 Null-Modem Cable
CD
DSR
RI
DCD DTR
RI
1
4
9
DB9
8
20
22
DB25
RS-422 Null-Modem Cable
CD
DSR RI
DTR
DB9
DB25
DTR
TxD
RTS
RxD CTS
DSR
RxD
CTS
TxD RTS
6
2
8
3
6
3
5
2
TxD
RTS
RxD CTS
RxD-
RxD+
TxD- TxD+
2
8
3
7
3
5
2
4
DeviceMaster Installation and Configuration Guide: 2000594 Rev. F