Table 23. Sensor information, event description, and service action for the 8348-21C
Sensor name (Sensor ID)
Watchdog (0x00)
Host Status (0x04)
Event description
v Timer Expired
v Reserved1
v Reserved2
v Reserved3
v Reserved4
v Hard Reset
v Power Down
v Power Cycle
v Timer Interrupt
Unknown
v S0/Go "Working"
v S1 "Sleeping with system h/w &
processor context maintained"
v S2 "sleeping, processor context
lost"
v S3 "sleeping, processor & h/w
context lost, memory retained"
v S4 "non-volatile sleep / suspend-to
disk"
v S5 / G2: "soft-off"
v S4 / S5: "soft-off"
v G3 mechanical Off
v Sleeping in an S1/S2/S3 State
v G1: Sleeping
v S5: entered by override
v Legacy ON state
v Legacy OFF state
Service action
No service action is required.
SEL events with OEM record c0 |
000e000 | 3a150xxxxxxx indicate that
a boot failed. Search for boot failure
SEL events that have a time stamp in
close proximity to the time stamp of
this SEL event. If events exist, go to
"Resolving a system firmware boot
failure" on page 4. If there are no
boot failure SEL events and the
system booted correctly, no service
action is required.
Go to Getting fixes and update the
system firmware to the most recent
level of firmware that is available. If
this SEL event continues to be logged
each time you power on the system,
go to "Collecting diagnostic data" on
page 109. Then, go to "Contacting
IBM service and support" on page
110.
No service action is required.