Table 19. OEM record c0 specific log information, description, and service action for an 8335-GTB (continued)
OEM record c0 specific log
information
3a2604yyyyyy
Table 20. OEM record c0 specific log information, description, and service action for an 8348-21C
OEM record c0 specific log
information
320a01xxxxxx
320a02xxxxxx
320exxxxxxxx
3a0400xxxxxx
3a0402xxxxxx
3a0701xxxxxx
3a0702xxxxxx
3a1100xxxxxx
3a1101xxxxxx
3a1503xxxxxx
3a1504xxxxxx
3a1601xxxxxx
3a1602xxxxxx
34
Problem analysis, system parts, and locations for the 8335-GCA, 8335-GTA, 8335-GTB, and 8348-21C
Description
All of the fans are missing or failed
Description
Phy read failure
Phy speed and duplex failure
OCC reset required
Chassis soft power off
Chassis soft reboot
Request for PNOR access
Release of PNOR access
Fan thread stopped
Fan thread started
Primary side boot failed
Golden side boot failed
Fan 1 failure
Fan 2 failure
Service action
Ensure that the fan power cable and
the disk and fan signal cable are
seated properly. If the problem
persists, replace the following items,
one at a time, until the problem is
resolved:
Note: Go to "8335-GTB locations" on
page 121 to identify the physical
location and removal and
replacement procedure.
v Power riser with time-of-day
battery slot
v Fan power cable
v Disk and fan signal cable
v Disk drive and fan card
Service action
If you are viewing this event from
the BMC, the missing or defective
cable is now operational and no
service action is required. Otherwise,
replace the missing or failed LAN
cable that attaches the console to the
system.
This event is for information only. No
service action is required.
A user initiated power off request
occurred. No service action is
required.
This event is for information only. No
service action is required.
Go to "Resolving a system firmware
boot failure" on page 4.
Go to "Resolving a system firmware
boot failure" on page 4.
Replace Fan 1. Go to "8348-21C
locations" on page 133 to identify the
physical location and removal and
replacement procedure.
Replace Fan 2. Go to "8348-21C
locations" on page 133 to identify the
physical location and removal and
replacement procedure.

Advertisement