IBM Power System 8335-GCA Manual page 74

Problem analysis, system parts, and locations
Hide thumbs Also See for Power System 8335-GCA:
Table of Contents

Advertisement

Table 22. Sensor information, event description, and service action for the 8335-GTB
Sensor name (Sensor ID)
Watchdog (0x00)
Host Status (0x04)
58
Problem analysis, system parts, and locations for the 8335-GCA, 8335-GTA, 8335-GTB, and 8348-21C
Event description
v Timer Expired
v Reserved1
v Reserved2
v Reserved3
v Reserved4
v Hard Reset
v Power Down
v Power Cycle
v Timer Interrupt
Unknown
v S0/Go "Working"
v S1 "Sleeping with system h/w &
processor context maintained"
v S2 "sleeping, processor context
lost"
v S3 "sleeping, processor & h/w
context lost, memory retained"
v S4 "non-volatile sleep / suspend-to
disk"
v S5 / G2: "soft-off"
v S4 / S5: "soft-off"
v G3 mechanical Off
v Sleeping in an S1/S2/S3 State
v G1: Sleeping
v S5: entered by override
v Legacy ON state
v Legacy OFF state
Service action
No service action is required.
SEL events with OEM record c0 |
000e000 | 3a150xxxxxxx indicate that
a boot failed. Search for boot failure
SEL events that have a time stamp
close to the time stamp of this SEL
event. If events exist, go to
"Resolving a system firmware boot
failure" on page 4. If there are no
boot failure SEL events and the
system booted correctly, no service
action is required.
Go to Getting fixes and update the
system firmware to the most recent
level of firmware that is available. If
this SEL event continues to be logged
each time you power on the system,
go to "Collecting diagnostic data" on
page 109. Then, go to "Contacting
IBM service and support" on page
110.
No service action is required.

Advertisement