Advertisement

Table 23. Sensor information, event description, and service action for the 8348-21C (continued)
Sensor name (Sensor ID)
Checkstop (0x0C)
Event description
IERR
v Thermal Trip
v Configuration Error
v Processor Automatically Throttled
v Correctable Machine Check Error
v Processor Presence Detected
v FRB1 BIST Failure
v FRB2 Hang In POST Failure
v FRB3 Processor Startup
Initialization Failure
v SMBIOS Uncorrectable CPU
Complex Error
v Processor Disabled
v Terminator Presence Detected
v Machine Check Exception
Service action
If this event immediately precedes a
system power off, no service action is
required. Otherwise, search for SEL
events that meet the following
criteria:
v The event has a time stamp in
close proximity to the time stamp
of this event.
v A service action keyword is
present. For a list of service action
keywords, see "Identifying service
action keywords in system event
logs" on page 36.
v Asserted is in the description.
If you found a SEL event that
matches the criteria, perform the
service action that is indicated in this
table for the SEL event. Otherwise, go
to "Collecting diagnostic data" on
page 109. Then, go to "Contacting
IBM service and support" on page
110.
No service action is required.
Go to "Collecting diagnostic data" on
page 109. Then, go to "Contacting
IBM service and support" on page
110.
Beginning troubleshooting and problem analysis
93