Table 21. Sensor information, event description, and service action for the 8335-GCA and 8335-GTA (continued)
Sensor name (Sensor ID)
All PGood (0x1C)
42
Problem analysis, system parts, and locations for the 8335-GCA, 8335-GTA, 8335-GTB, and 8348-21C
Event description
v Interlock Power Down
v Power Off Power Down
v Power Cycle
v 240VA Power Down
v AC Lost
v Soft Power Control Failure
v Power Unit Failure Detected
v Predictive Failure
Service action
No service action is required.
v Ensure that ac power is supplied
to the rack.
v Ensure that the system power
cords are plugged tightly into both
the power supply and the rack
power distribution unit (PDU) for
both system power supplies.
v Ensure that the system was not
powered off.
v Ensure that ac power is supplied
to the rack.
v Ensure that the power supply
cords are plugged tightly into the
power supplies and the rack PDU
unit.
v Ensure that the system was not
powered off.
v Check for service action required
SEL events for the power supply
sensor. If any exist, follow the
service action that is specified in
"Identifying a service action by
using sensor and event information
for the 8335-GCA and 8335-GTA"
on page 37.