Table 21. Sensor information, event description, and service action for the 8335-GCA and 8335-GTA (continued)
Sensor name (Sensor ID)
v CPU Func 1 (0x0C)
v CPU Func 2 (0x0E)
Event description
v IERR
v Transition to Non-recoverable
v Predictive Failure
v Thermal Trip
v FRB1 BIST Failure
v FRB2 Hang In POST Failure
v FRB3 Processor Startup
Initialization Failure
v Configuration Error
v SMBIOS Uncorrectable CPU
Complex Error
v Processor Disabled
v Terminator Presence Detected
v Processor Automatically Throttled
v Machine Check Exception
v Correctable Machine Check Error
v State Deasserted
v Device Disabled
v Transition to Critical from Less
Severe
v Transition to Non-recoverable from
Less Severe
v Transition to Critical from
Non-recoverable
v Processor Presence Detected
v State Asserted
v Device Enabled
v Transition to OK
v Transition to Non-Critical from OK
v Transition to Non-Critical from
More Severe
v Monitor
v Informational
Service action
If the sensor name is CPU Func 1,
replace CPU 1. If the sensor name is
CPU Func 2, replace CPU 2. Go to
"8335-GCA and 8335-GTA locations"
on page 111 to identify the physical
location and removal and
replacement procedure.
No service action is required.
Beginning troubleshooting and problem analysis