Technical Data; Variants; Accessories - Riello Burners RS Series Installation, Use And Maintenance Instructions

Forced draught gas burners, progressive two-stage operation
Table of Contents

Advertisement

TECHNICAL DATA

MODEL
TYP
OUTPUT
(1)
FUEL
- Net caloriÞc value
- Absolute density
- Max. delivery
- Pressure at maximum delivery
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE LEVELS
(3)
APPROVAL
(1) Reference conditions: Ambient temperature 20 ° C - Barometric pressure 1000 mbar - Altitude 100 m s.l.m.
(2) Pressure at test point 16)(A)p.6, with zero pressure in the combustion chambre, with open gas ring 2)(B)p.14 an maximum burner output
(3) Sound pressure measured in manufacturers combustion laboratory, with burner operating on test boiler and at maximum rated output.

VARIANTS

:
MODEL
ELECTRICAL
SUPPLY
RS 70
three-phase
three-phase
three-phase
three-phase
RS 100
three-phase
three-phase
three-phase
three-phase
RS 130
three-phase
three-phase
three-phase
three-phase

ACCESSORIES

(optional):
¥
KIT FOR LPG OPERATION: The kit allows the RS 70-100-130 burners to operate on LPG.
BURNER
OUTPUT
BLAST TUBE LENGTH
CODE
¥
GAS TRAIN ACCORDING TO REGULATION EN 676 (with valves, pressure governor and Þlter) : see page 16.
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.
2nd stage
Mcal/h
min. 1st stage
Mcal/h
kWh/Nm
Mcal/Nm
kg/Nm
(2)
° C max 60
V1 - V2
W max
BLAST TUBE
STATUS /
LENGHT MM
LED PANEL
250
STATUS
385
STATUS
250
LED PANEL
385
LED PANEL
250
STATUS
385
STATUS
250
LED PANEL
385
LED PANEL
280
STATUS
415
STATUS
280
LED PANEL
415
LED PANEL
RS 70
242 ¸ 814
kW
mm
250
3010097
3010098
RS 70
821 T1
kW
465 - 814
400 - 700
kW
192
165
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
G25
3
10
8,6
8,6
7,4
3
3
0,71
0,78
3
81
94
Nm
/h
mbar
10,3
15,2
¥ Intermittent (min. 1 stop in 24 hours).
¥ Two-stage (high and low ßame) and single-stage (all-nothing)
Boilers: water, steam, diathermic oil
° C
0 - 40
V
230 - 400 with neutral ~ +/-10%
Hz
50 - three-phase
rpm
2800
W
1100
V
220/240 - 380/415
A
4,8 - 2,8
230 V - 1 x 8 kV
I1 - I2
1 A - 20 mA
1400
IP 44
90/396 - 89/336 - 73/23 - 92/42
dBA
75
CE
0085AP0944
COUNTRY
IT-AT-GR-DK-FI-SE
ES-GB-IE-PT
RS 100
349 ¸ 1163
385
250
3010099
4
RS 100
822 T1
698 - 1163
600 - 1000
232
200
G20
G25
10
8,6
8,6
7,4
0,71
0,78
116
135
9,3
13,7
2800
1500
220/240 - 380/415
5,9 - 3,4
1800
77
0085AP0945
CATEGORY
II
2H3B/P
II
2H3P
NL
II
2L3B/P
FR
II
2Er3P
DE
II
2ELL3B/P
BE
I
2E(R)B,
LU
II
2E3B/P
466 ¸ 1512
385
280
3010100
3010101
GB
RS 130
823 T1
930 - 1512
800 - 1300
372
320
G20
G25
10
8,6
8,6
7,4
0,71
0,78
151
175
8,6
12,7
2800
2200
220/240 - 380/415
8,8 - 5,1
2600
78,5
0085AP0946
I
3P
RS 130
415
3010102

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs 130Rs 70Rs 100

Table of Contents