A Typical System - Bentel Security Omnia 8/L Manual

Table of Contents

Advertisement

Step 3
Step 4
Step 5
Step 6

A Typical System

Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
+
INSTALLATION
Press
to access programming.
Open the Panel and service as required.
The OPEN LED on the keypads will stay ON until the Panel is closed
again. No alarms will be generated during this phase.
Close the Panel.
Press
to exit the programming phase.
Figure 2 illustrates a typical system.
Incoming telephone line connection
Signalling device connections----indoor siren and self-powered siren
Connection of a burglar sensor to line L1
Connection of three fire sensors to line L8
Connection of the Tamper line to the siren
Connection of additional devices (Keypad and Key reader) to the BPI bus
Please note:
Line L1 must be programmed as Double Balanced. This configuration
provides tamper detection, and requires 2 wires only.
Line L8 must be programmed as Fire, and the auxiliary output (terminal
42[O4]) as Fire GND ---- Normally Closed.
Not all Alarm line connections are illustrated, however, burglar sensors
must be connected as per line L1, and fire sensors as per line L8.
Use shielded cable----one end must be connected to the Panel ground and
the other to the device ground.