RIKA Memo Gsm Operating Manual page 31

Hide thumbs Also See for Memo:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 26
Stoves with Touchscreen
Command Input and Responses from Stove Software
Version 1.12/Touchscreen Software Version 1.22
(case insensitivity)
Start in the Manual Mode by specifying the heat output without
heating time:
Please note the space between the numerical
for example:
code and specification! The response (SMS reply)
1234 M70
reads: Manual Mode 70%
Start in the Automatic Mode by specifying the heat output with
heating times preassigned (If no heating times are stored , the stove
remains in standby)
for example:
The response (SMS reply) reads:
Automatic Mode 70 %, Heating Times Active
1234 A70
Start in the Comfort Mode by specifying the target room temperature
without heating times:
for example:
The response (SMS reply) reads:
Comfort Mode 22°C
1234 C22
Start in the Comfort Mode and specify the target room temperature
with heating times preassigned:
for example:
The response (SMS reply) reads:
Comfort Mode 22°C, Heating Times Active
1234 CT22
Switching off the pellet burner:
for example:
The response (SMS reply) reads:
STOVE OFF
1234 OFF
Frost Protection
It is possible to activate and deactivate the function frost protection
here:
for example:
The response (SMS reply) reads:
FROST PROTECTION ON
1234 FON
for example:
The response (SMS reply) reads:
FROST PROTECTION OFF
1234 FOFF
Operating parameter queries
Various set parameters are sent here (status, day heating times, actual
room temperature, etc.):
The response (SMS reply) reads:
Stove ON
for example:
AUTOMATIC MODE 65%
1234 ?
BURN OFF
HT1 ...
The current status, for example, could be: inactive, ignition, manual
mode, cleaning phase, etc.
HT1: Heating time 1 (if no heating time is set, 00:00 is displayed)
HT2: Heating time 2 (if no heating time is set, 00:00 is displayed)
RT: Actual room temperature (only with connected room sensor)
Warnings and Errors
If an error occurs during operation, the respective error is sent by
SMS message to the number saved last.
Important:
Not all warnings and errors occur in all stoves!
Please consult the manual of your stove for further informations.
Warnings / Errors
If the code text has an error
such as: 4213 A50
If a wrong command was sent
(1234 bos).
Resetting GSM module
(see notice below)
There is no room sensor
connected. Please switch to
manual mode!
The room sensor lost the
connection during comfortmode
- please switch to manual mode!
Pellet hopper lid open
Door open
Not enough low pressure
No pellets
Not ignited
Grid defect
Flame sensor defect
Dischargemotor defect
Insertionmotor defect
Dischargemotor blocked
Insertionmotor blocked
Air flaps defect
Burnback flap
Fan defect
Not enough low pressure
(permanent)
Stove overheated
Note:
Warning messages are not sent automatically. If during an SMS
request or command a warning message is on the display of the
stove, this warning is returned by SMS. For example as: Door open.
This is not possible when you suppress your telephone number!
Note:
If the modem is forced to send, for example through information
SMS of the network operator, SMS reply to a number, it will be
restarted for security reasons after five runs and sends a notification
to the stored number:
FAILURE: sending SMS - resetting GSM module
The modem is fully operating again after the automatic reboot.
Text-message
FAILURE: code error
FAILURE: text error
FAILURE: sending SMS - resetting
GSM module
FAILURE:
no
room
sensor
available
WARNING: room sensor signal
lost - please switch to MANUAL
MODE
WARNING: pellet cover open
WARNING: door open
WARNING: not enough low
pressure
FAILURE: no pellets
FAILURE: not ignited
FAILURE: grid defect
FAILURE: flame sensor defect
FAILURE: dischargemotor defect
FAILURE: insertionmotor defect
FAILURE: dischargemotor blocked
FAILURE: insertionmotor blocked
FAILURE: air flaps defect
FAILURE : burnback flap
FAILURE: ID fan defect
FAILURE: low pressure control
FAILURE: safety temperature
limiter
|31
30

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

ComoPicoRevoInternoTopo

Table of Contents