Wilo Drain LPC Series Installation And Operating Instructions Manual
Wilo Drain LPC Series Installation And Operating Instructions Manual

Wilo Drain LPC Series Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Wilo-Drain LPC
D
Einbau- und Betriebsanleitung
GB
Installation and operating instructions
F
Notice de montage et de mise en service

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Drain LPC Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wilo Drain LPC Series

  • Page 1 Wilo-Drain LPC Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service...
  • Page 2 Fig.1: Fig.2: Fig.3: max. 7,5 m min. 0,1 m...
  • Page 3 Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service...
  • Page 5: Einbau- Und Betriebsanleitung

    • Produkt auf Transportschäden überprüfen, Das Personal für die Montage muss die entspre- • Transportschäden in den Lieferpapieren doku- chende Qualifikation für diese Arbeiten aufwei- mentieren, vom Spediteur gegenzeichnen lassen sen. und umgehend den Hersteller informieren. Einbau- und Betriebsanleitung Wilo-Drain LPC...
  • Page 6: Bestimmungsgemäße Verwendung

    5 Angaben über das Erzeugnis verschließen. 5.1 Typenschlüssel 4 Bestimmungsgemäße Verwendung Beispiel: LPC 40/19 3-400-50-2 M Die Pumpen der Baureihe Wilo-Drain LPC dienen Selbstansaugende Pumpe (Lifting Pump) zur Förderung von Schmutzwasser mit geringem Grauguss (cast iron) Feststoffanteil. Einsatzgebiete: Nennweite (DN 40) •...
  • Page 7: Beschreibung Und Funktion

    überschritten wird. Unsachgemäße Aufstellung kann die Pumpe 6 Beschreibung und Funktion beschädigen. • Bei mobilen Pumpen auf sichere Aufstellung Die Pumpen der Baureihe Wilo-Drain LPC sind achten. selbstansaugende Kreiselpumpen mit offenem • Bei Festinstallation Grundplatte mit Fundament Mehrkanallaufrad. Die Antriebswelle und verschrauben.
  • Page 8 (6- bis 8-facher Nennstrom) ausreichen ern. (Fig. 2) • Geeignete 4-adrige elektrische Anschlussleitung bereithalten, Leitungsquerschnitt beachten: Anschlussspannung LPC 40 LPC 50 3~230 V 4 x 1,5 mm 4 x 1,5 mm 3~400 V 4 x 1,5 mm 4 x 1,5 mm WILO AG 08/2007...
  • Page 9: Wartung

    Fällen auch die Gleit- nungsversorgung unterbrechen und gegen Wie- ringdichtung erneuert werden. Es wird empfohlen dereinschalten sichern. diese Arbeiten durch den Wilo Kundendienst WARNUNG! Verletzungsgefahr! durchführen zu lassen. An rotierenden Bauteilen besteht Verletzungs- Angaben zu Wartungsarbeiten der Benzin-Ver- gefahr bei Berührung.
  • Page 10: General Information

    • check the product for any transport damage, The installation personnel must have the appro- • document the transport damage in the shipping priate qualification for this work. documents, have it signed by the forwarding agent and inform the manufacturer immediately. WILO AG 08/2007...
  • Page 11: Product Details

    Example: LPC 40/19 3-400-50-2 M 4 Intended use Self-priming pump (lifting pump) The pumps of the Wilo-Drain LPC series are for Grey cast iron pumping wastewater with a low proportion of Nominal width (DN 40) solid particles. Areas of application: Maximum delivery head [m] •...
  • Page 12: Description And Function

    • For a fixed installation, screw the base plate to 6 Description and function the foundation. The pumps of the Wilo-Drain LPC series are self- Installation example (fig. 3) priming centrifugal pumps with open multi- Fig. 3 shows an example of a fixed installation with vane impeller.
  • Page 13 • Keep a suitable 4-core electrical connection line ready and observe the line diameter: Anschlussspannung LPC 40 LPC 50 3~230 V 4 x 1,5 mm 4 x 1,5 mm 3~400 V 4 x 1,5 mm 4 x 1,5 mm Installation and operating instructions Wilo-Drain LPC...
  • Page 14: Maintenance

    Have an electrician find the cause and elim- inate it. If the fault cannot be fixed, please contact your regional specialist or your nearest Wilo cus- tomer service location or representative. 11 Spare parts Spare parts can be ordered from your local spe- cialist and/or via Wilo customer service.
  • Page 15: Notice De Montage Et De Mise En Service

    2.2 Qualification du personnel reau de livraison, le faire signer par le transporteur Il convient de veiller à la qualification du personnel et informer immédiatement le fabricant. amené à réaliser le montage. Notice de montage et de mise en service Wilo-Drain LPC...
  • Page 16: Caractéristiques Du Produit

    • Refermer l'orifice de contrôle/de vidange. 5.1 Dénomination 4 Utilisation conforme Exemple: LPC 40/19 3-400-50-2 M Les pompes de la gamme Wilo-Drain LPC sont Pompe autoamorçante (Lifting Pump) destinées au pompage d’eaux claires, sales ou peu Fonte grise (cast iron) chargées. Domaines d'application : Diamètre nominal (DN 40)
  • Page 17: Description Et Fonctionnement

    L'arbre d'entraînement et l’orifice d'aspiration sont disposés à l'horizon- tale et l’orifice de refoulement à la verticale. Description de la pompe (Fig. 1) : 1 Corps de pompe 2 Orifice d'aspiration Notice de montage et de mise en service Wilo-Drain LPC...
  • Page 18 • Pompe mobile : • Protéger les raccordements électriques de l'humi- Amener la pompe avec chariot manuel vers le lieu dité. d'utilisation, la placer sur une surface plane et l'immobiliser pour l'empêcher de se mettre à rou- ler. WILO AG 08/2007...
  • Page 19: Entretien

    • Avant de procéder à des travaux sur des compo- sants électriques, couper l'alimentation en ten- sion et la protéger contre toute remise en marche inopinée. Notice de montage et de mise en service Wilo-Drain LPC...
  • Page 20 Faire rechercher et éliminer la cause par un électricien spécialisé. S'il n'est pas possible de remédier au défaut, faire appel à un installateur agréé, au SAV Wilo le plus proche ou à son représentant. 11 Pièces de rechange Les pièces de rechange doivent être commandées auprès de l'installateur agréé...
  • Page 21 Compatibilité électromagnétique- directive 91/263/EWG 92/31/EWG 93/68/EWG Angewendete harmonisierte Normen, insbesondere: EN 809 Applied harmonized standards, in particular: EN 61000-6-1 Normes harmonisées, notamment: EN 61000-6-2 EN 61000-6-3 EN 61000-6-4 Dortmund, 05.12.2006 Erwin Prieß WILO AG Quality Manager Nortkirchenstraße 100 44263 Dortmund Document: 2084186.1...
  • Page 22 EN 61000-6-3 AB-Makina Standartları 98/37/EG Elektromanyetik Uyumluluk 89/336/EWG ve takip EN 61000-6-4 98/37/EG eden, 91/263/EWG, 92/31/EWG, 93/68/EWG EG-89/336/EWG 91/263/EWG 92/31/EWG, 93/68/EWG Kısmen kullanılan standartlar: WILO AG Erwin Prieß Nortkirchenstraße 100 Quality Manager 44263 Dortmund...
  • Page 23 Great Britain Spain WILO Pumps Ltd. Poland WILO SALMSON (Beijing) WILO (U.K.) Ltd. WILO Ibérica S.A. 621-807 Gimhae WILO Polska Sp. z.o.o. Pumps System Ltd. DE14 2WJ Burton- 28806 Alcalá de Henares Gyeongnarn 05-090 Raszyn WILO USA LLC 101300 Beijing...
  • Page 24 WILO AG Nortkirchenstraße 100 44263 Dortmund Germany T 0231 4102-0 F 0231 4102-7363 wilo@wilo.de www.wilo.de Wilo-Vertriebsbüros in Deutschland G1 Nord G3 Sachsen/Thüringen G5 Südwest G7 West WILO AG WILO AG WILO AG WILO AG Vertriebsbüro Dresden Vertriebsbüro Stuttgart Vertriebsbüro Düsseldorf Vertriebsbüro Hamburg...