Wilo DrainLift SANI-M Installation And Operating Instructions Manual
Wilo DrainLift SANI-M Installation And Operating Instructions Manual

Wilo DrainLift SANI-M Installation And Operating Instructions Manual

Hide thumbs Also See for DrainLift SANI-M:

Advertisement

Quick Links

Pioneering for You
Wilo-DrainLift SANI-M
en
Installation and operating instructions
·
2552853 • Ed.04/2024-12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DrainLift SANI-M and is the answer not in the manual?

Questions and answers

Summary of Contents for Wilo DrainLift SANI-M

  • Page 1 Pioneering for You Wilo-DrainLift SANI-M Installation and operating instructions · 2552853 • Ed.04/2024-12...
  • Page 2 DrainLift SANI-M https://qr.wilo.com/481...
  • Page 3: Table Of Contents

    7 Commissioning.................  19 Staff qualifications ............. 20 Operator responsibilities ........... 20 Operation ................ 20 Test run ................ 20 Follow-up time.............. 20 Setting the venting screw .......... 21 8 Operation..................  21 Application limits .............. 21 During operation.............. 22 Emergency operation ............ 22 Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 4: General

    All rights reserved. Subject to change Wilo reserves the right to change the listed data without prior notice and is not liable for technical inaccuracies and/or omissions. The illustrations vary from the original and are in- tended as a sample representation of the product.
  • Page 5: Staff Qualifications

    Safety helmet (EN 397): conforms to the standard and protects against lateral deforma- tion (If lifting accessories are used) Protective equipment: cleaning work • Safety gloves: 4X42C + Type A (uvex protector chemical NK2725B) • Safety glasses: uvex skyguard NT Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 6: Electrical Work

    The mentioned branded articles are non-binding suggestions. Equivalent products from other brands can also be used. The prerequisite is obeying the standards mentioned. WILO SE accepts no liability for the articles mentioned regarding their conformity to the applicable standards. •...
  • Page 7: During Operation

    • Sewage with faeces • Sewage without faeces The C version is for pumping aggressive fluids: • Condensate from boilers CAUTION! Do not pump pure condensate. Only pump condensates mixed with sewage. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 8: Improper Use

    Pre-wired switchgears for automatic operation: Wilo-Control MS-L • Collective fault signal with potential-free contact • Integrated and mains-independent alarm • Adjustable follow-up time • 1.5 m connection cable with attached plug Wilo-Control EC-L Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 9: Materials

    • I = I type (AU, NZ, ZH) • CEE = different CEE plugs (16 A/32 A, 3-poles; 32 A, 1-pole) • O= without cable Technical data Approved field of application Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 10: Manufacturer Date

    HT double socket DN/OD 75 for ventilation connection • HT double socket DN/OD 50 for drain connection • Inlet set with hole saw 124 mm (5 in) and seal for HT pipe DN/OD 110 • Floor fixation set Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 11: Accessories

    Coil up connection cables and attach to the motor. • Seal open ends of the connection cables and plugs in a watertight manner. • Obey the instructions for switchgear storage. • Tightly seal all open connections. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 12: Installation And Electrical Connection

    (i.e. tripping, damage during operation). Examine if the cable cross- section and the cable length are sufficient for the selected installation type. • The switchgear is not flood-proof. Install the switchgear at an sufficient height. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 13 Install a gate valve on the inlet side and on the discharge pipe side downstream of the non-return valve. 6.4.3 Work steps Install the lifting unit in these steps: • Preparing the installation. • Installing the lifting unit . • Connecting the discharge pipe. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 14 To prevent the switchgear from flooding, fasten the switchgear to the wall at a suffi- cient height (see switchgear instructions). 10. Lay the connection cable. Obey applicable regulations. ▶ Lifting unit is installed. Next step: Connecting the discharge pipe. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 15 Discharge pipe is connected. Next step: Connecting the inlet. 6.4.7 Connecting the inlet The inlet can be located in the areas indicated on the rear wall, both side walls and the tank roof, as desired. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 16 ✓ Inlet pipe is installed to the collection tank. The consulting documents are obeyed. ✓ Installation material are prepared: 1x hole saw 124 mm (5 in) 1x seal DN/OD  110 1x pipe clamp Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 17 Manually pump out the collection tank for maintenance or if the lifting unit malfunctions. It is recommended to install a diaphragm hand pump. CAUTION! If the lifting unit malfunc- Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 18: Electrical Connection

    – DrainLift SANI-M…M/…: CEE 7/7 (Schuko) Three-phase current: – DrainLift SANI-M…T/…: CEE 16A, 3P+N+PE, 6 h, clockwise rotating field 6.5.3 Switchgear The switchgear is pre-wired and factory-set. Obey local regulations to lay all connection cables to the switchgear and mains connection. CAUTION! To prevent the switchgear from flooding, install it at a sufficient height.
  • Page 19: Commissioning

    NOTICE! For the location of DIP switch 3, refer to the installation and operating instruc- tions for the switchgear. Wilo-Control EC-L switchgear For the Wilo-Control EC-L switchgear, set the switching points through the values in the menus: Switching points Inlet height: 180 mm (7 in) •...
  • Page 20: Staff Qualifications

    Follow-up time The follow-up time is pre-set at the factory to 3 seconds. Adjust the follow-up time as ne- cessary for these points: • Increasing the usable volume for each pumping process. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 21: Setting The Venting Screw

    Max. short-time fluid temperature: 65 °C (149 °F), 5 min • Ambient temperature: 3 ... 40 °C (37 ... 104 °F) • Maximum switching frequency: 60/h • Operating mode: – SANI-M ... /1 ...: S3 10% – SANI-M ... /4 ...: S1 Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 22: During Operation

    • Install the electrical connections and switchgear at a flood-proof height. • Obey the maximum flooding level and flooding time for the lifting unit. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 23 Danger through alone working! Working in chambers, narrow rooms, and in areas with a risk of falling can be dangerous. Do not work alone. • Only do this work with a second person. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 24 1 year for detached houses Record all maintenance and repair work in a log. The log must be signed by the qualified staff and the operator. Perform a test run after the maintenance work. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...
  • Page 25 Only return the product to a designated and permitted collection point. • Obey local regulations. Consult your local municipality, the nearest waste disposal site, or your retailer for a correct disposal. See for more http://www.wilo-recycling.com information about recycling. Installation and operating instructions • Wilo-DrainLift SANI-M • Ed.04/2024-12...