Download Print this page

Xylem Lowara Q-smart Installation, Operation & Maintenance Manual page 33

Single phase electronic control panel

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 32
2 Transportation and Storage
Inspection and delivery
2.1
1.
Check the outside of the package.
2.
Notify our distributor within eight days of the
delivery date, if the product bears visible signs
of damage.
3.
Open the carton.
4.
Remove packing materials from the product.
Dispose of all packing materials in accord-
ance with local regulations.
5.
Inspect the product to determine if any parts
have been damaged or are missing.
6.
Contact the seller if anything is out of order.
Transportation and guidelines
2.2
Precaution
WARNING:
Observe the accident prevention
regulations in force.
Check the gross weight indicated on the package
in order to select the proper lifting equipment.
Position and fastening
Make sure that the unit is securely fastened during
transportation and cannot roll or fall over. The prod-
uct must be transported at an ambient temperature
between -10°C and 70°C (14°F to 158°F) with a
non-condensing humidity of <90%, and protected
against dirt, heat sources, and mechanical damage.
Storage guidelines
2.3
Storage location
2.3.1
NOTICE:
Protect the product against humidity, dirt,
heat sources, and mechanical damage.
The product must be stored at an ambient
temperature between -10°C and 70°C (14°F
and 158°F) and a non-condensing humidity
below 90%.
3 Product Description
Product overview
3.1
The Q-SMART control panel is a single-phase
electronic control panel intended to be used with 1
or 2 single-phase electric pumps for different fixed
speed applications.
It is suitable for pressurisation, emptying or sew-
age systems. Check your type of installation and
change the parameters (see sections 5.4.3,
and 10.1) accordingly.
Product name
3.2
Example: Q-SMART 10/15/D 12A
Q-
Trade name of control panel.
SMART
Mains power supply, single-phase
1x230Vac 50/60Hz
10
Number of pumps that can be connected
10: One
20: Two
15
Nominal motor power kW x 10
15=1.5kW x 10
D
Default software application
D: sewage/lifting
B: booster/pressurisation
12A
Maximum current absorbed by one
electric pump
Technical data
3.3
Tab 1
Standard version
Control
panel
Q-SMART 10
model
Rated
voltage
1x230VAC (-15% to +10%)
input (Uin)
Rated input fre-
en - Original instructions
5.4.4
Q-SMART 20
50/60 Hz
33

Advertisement

loading