Tmaa01-05 Options-Extender Board; Changing The Options-Extender Links - Tait TM8000 Series Accessories Manual

Hide thumbs Also See for TM8000 Series:
Table of Contents

Advertisement

3

TMAA01-05 Options-Extender Board

D-range hood
parts
D-range plug
internal options
connector
options-
extender
board
external options
connector
options-extender
installation parts
internal options
external options
loom
cover seal
3.1

Changing the Options-Extender Links

TM8000 Mobile Radio Accessories Manual
March 2004 © Tait Electronics Limited
The TMAA01-05 options-extender board provides external
access to most of the signal lines provided by the radio's internal
options connector.
The options-extender board fits inside the radio in the options
cavity and is connected to the main PCB by the internal options
connector and loom.
The internal options connector signals are then made available on
the high-density 15-way D-range connector mounted on the
options-extender board. This connector fits through the external
options connector hole provided in the radio chassis.
Important
Important
The options-extender board configuration must be completed before the
board is installed in the radio, as the top side of the options-extender board
is not accessible once the board is screwed to the radio lid.
Important
This equipment contains devices which are susceptible to
damage from static discharges. Refer to
on page 13
The options-extender board has various link options which allow the user
to re-configure the outputs available on the external options connector. The
outputs that can be made available by changing linking resistors are:
the 5V supply line, and
I
the RX_BEEP_IN line.
I
In both cases, these lines replace other lines that are available when the
linking resistors are in the factory-set configuration. Note that there is no
external connection available for the RX_AUD line.
The radio does not meet the IP54 protec-
tion standard once an options-extender
board has been installed unless the exter-
nal options cover seal is installed.
To comply with EN 301 489-5, all
cables connected to the external options
connector must be less than three metres
(10 feet) in length.
for more information.
TMAA01-05 Options-Extender Board