5

Service and maintenance

Pull out the mains plug before start-
ing on any maintenance work!
The portable band saw Z 5 Ec / Z 4 Ec is designed
with a low maintenance requirement. The ball bear-
ings are greased for life.
The machine must be cleaned of dust deposits at
regular intervals. When doing so, clean the air vents
on the motor using a vacuum cleaner.
The saw blade wheels used on the machine must be
freed from resin regularly.
6

Troubleshooting

The determination of the causes of existing defects and their elimination always require
increased attention and caution. Pull out the mains plug before hand!
Some of the most frequent defects and their causes are listed in the following chart. In case of other defects,
contact your dealer or the MAFELL customer service.
Defect
Machine cannot be switched on
Undervoltage switch-off
Saw blade jamms
Chip ejection blocked
7

Optional accessories

Adapter (pair) for parallel guide fence to be linked to the guide - rail
Guide-rail cpl., 3 m (9.8 ft)
Guide-rail, extension piece, 1.5 m (4.9 ft)
Guide-rail, one-piece, cpl. 3 m (9.8 ft)
Carriage Z 5 Ec / Z 4 Ec
Z 5 Ec - Band saw blades, 10 pieces 1752 x 6 x 0.65 4 teeth/1"
Band saw blades, 10 pieces 1752 x 6 x 0.65 6 teeth/1" small teeth
Band saw blades, 10 pieces 1752 x 8 x 0.65 4 teeth/1"
Band saw blades, 10 pieces with double-sided toothing
1752 x 8 x 0.65 4 teeth/1"
Z 4 Ec - Band saw blades, 10 pieces 1592 x 6 x 0.65 4 teeth/1"
Band saw blades, 10 pieces 1592 x 6 x 0.65 6 teeth/1" small teeth
Band saw blades, 10 pieces 1592 x 8 x 0.65 4 teeth/1"
Band saw blades, 10 pieces with double-sided toothing
1592 x 8 x 0.65 4 teeth/1"
Only use our special grease, order number 049040
(1 kg tin), for all lubrication spots.
After a prolonged period of operation, users are rec-
ommended to have the machine checked by an
authorized MAFELL customer service shop.
5.1
Storage
If the machine is out of service for a lengthy period of
time, it should be thoroughly cleaned (see chapter 5).
Spray bright metal panels with a rustproofing agent.
Store the machine only in dry rooms, where it is pro-
tected against weathering.
Cause
No mains voltage
No network voltage
(voltage interruption)
Blunt saw blade
Wood is too damp
Extended operation without extraction
-17-
Elimination
Check power supply
Switch the machine off and back on
Renew saw blade
Connect to an external extractor, e.g.
portable dust extractor
Ref. No. 037 195
Ref. No. 037 037
Ref. No. 036 553
Ref. No. 200 672
Ref. No. 202 110
Ref. No. 092 335
Ref. No. 092 333
Ref. No. 092 336
Ref. No. 092 337
Ref. No. 092 348
Ref. No. 092 347
Ref. No. 092 349
Ref. No. 092 350

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z 4 ec

Table of Contents