INSTALLATION INSTRUCTIONS (cont.)
ELECTRICAL CONNECTIONS U.K.
All electrical work should be carried out only by
a suitably qualified and competent person, in
strict accordance with national and local safety
regulations.
Ensure that power is not connected to the
appliance while installation work is being
carried out.
The cabinet is supplied as standard in two
versions suitable for connection to:-

230 volt single phase:
fuse rating 32 amp.

400 volt three phase and neutral:
fuse rating 3 x 10 amp.
NOTE:
The voltage, total load and fuse rating details
can be found on the data plate
on the inside of the cabinet.
The cabinet is not supplied with a mains cable.
The size and type of cable should be
determined by a qualified electrician to suit the
power
supply
and
the
installation.
Connection should be made via a suitable
isolator which complies with national and local
safety regulations, and the on/off switch should
be easily accessible for any servicing work.
When switched off there must be an all-pole
contact gap of 3mm in the isolation switch
(including switch, fuses and relays according to
VDE 0660). For additional safety it is advisable
to include a residual current devise (RCD)
within the installation.
Installation and Operating Manual
All supply cables into the cabinet should be
clamped using the glands fitted to the top
panel. The top fascia panel should be re-
moved to access the terminal connecting
block. Remove
be removed.
refitted before the machine is operated.
NOTE:
Connecting external devices.
A terminal block inside the control console is
wired and labelled to accept an external duct-
ing fan and coin/token operated mechanism if
required.
location
of
the
WARNING: This appliance must
earthed.
competent person.
The fascia panel can now
Ensure that all panels are
If in any doubt consult a