Replacing The Ac Fuse - Extron electronics DXP Series User Manual

Serial digital video matrix switchers
Table of Contents

Advertisement

im Vertrieb von

Replacing the AC fuse

www.camboard.de
CAMBOARD Electronics
6.
Reinitialize the switcher to recognize the new IC as follows:
Connect the power cord to the AC power source.
a.
b.
Press and hold the Enter button while you connect the power cord to the
switcher.
c.
Continue to hold the Enter button until the power up sequence is
completed (all front panel buttons cycle on and off from left to right lit
green, right to left lit red, and left to right lit amber).
d.
Release the Enter button.
7.
Ensure that the switcher is working properly.
8.
If the switcher was removed from a rack, remove its power cord, reattach the
switcher to the rack, and reconnect the power cord.
9.
Reconnect the input and output cables.
The AC fuse on the power supply board is a user-replaceable component. Replace
the AC fuse as follows:
1.
Follow the instructions in Opening the switcher on page 6-2 to gain access to the
interior of the switcher.
Locate the fuse on the power supply board (figure 6-2), and remove it from its
2.
retaining clips.
3.
If test equipment is available, you can check the fuse.
4.
Place a new 2.5 A/250V fast-blow fuse in the retaining clips.
5.
Reinstall the switcher's front panel and cover. See Closing the switcher on
page 6-2.
If you choose to check the switcher for proper operation before putting the
cover back on, ensure that tools and hands are outside the switcher, and
then connect the power cord to the unit and to an AC source. The
switcher should power up normally. Unplug the AC power cord, and
reinstall the cover.
6.
Attach the power cord to the switcher and to the AC power source. Make
sure the switcher is working properly.
7.
If the switcher was removed from a rack, remove its power cord, reattach the
switcher to the rack, and reconnect the power cord.
8.
Reconnect the input and output cables.