8.5

CHANGING THE ROUND JET NOZZLE

8.5.1 REMOVING THE ROUND JET NOZZLE

Procedure:
1. Pull off deflector cone.
2. Unscrew union nut from gun housing.
3. Take union nut with nozzle system off gun body.
The nozzle system remains inserted in the
union nut.
Note:
If the nozzle system doesn't remain inserted
in the union nut, the nozzle system and union
nut must be replaced.
4. Press nozzle system out of union nut by gently
pressing on deflector cone sleeve.
5. Remove powder residues from the removed
parts and from the spray gun.
Note:
Never place the spray gun or parts of the spray
gun in cleaning agent.
As a rule, the protective wedge needs to be
checked for wear and replaced if necessary.