8.4

CHANGING THE FLAT JET NOZZLE

8.4.1 REMOVING THE FLAT JET NOZZLE

Procedure:
1. Unscrew union nut from gun housing.
2. Take union nut with nozzle system off gun body.
The nozzle system remains inserted in the union nut.
Note:
If the nozzle system doesn't remain inserted in the union nut,
the nozzle system and union nut must be replaced.
3. The parts can be separated by gently pressing the sliding ring
on the flat jet nozzle.
4. Remove powder residues from the removed parts and from
the manual gun.
Note:
Never place the manual gun or parts of the manual gun in
cleaning agent.
As a rule, the protective wedge needs to be checked for
wear and replaced if necessary.