WAGNER PEM-X1 CG Operating Manual page 30

Powder cup gun
Table of Contents

Advertisement

VERSION 05/2019
14 LED display: "Automatic gun"
– Lights up, when an automatic gun is connected
15 Push button: "Standby"
– To switch into standby mode
– High voltage and powder feed cannot be activated in this mode
– To reactivate normal mode, press the button again
16 LED display: "Standby"
– Lights up when the device is in standby mode
17 Push button: "Flush"
– To activate the injector and the hose flushing
18 LED display: "Flush"
– Lights up blue, when the flush function is activated
19 LED display, 7 segments, three-digit number
– Indicates the exact value depending on the activated function:
"Total air volume; atomizing, ionizing and Tribo air; additional recipes; high voltage;
current limitation; powder quantity"
– Display showing error number in the event of warnings and malfunctions
20 Push button: "Total air volume"
– To activate the function, the value is precisely adjusted with rotary controller 24
and is indicated in LED display 19
– Adjusting range: 2-6 m³/h
– Resolution: 0.05 m³/h
21 Push button: "Atomizing, ionizing and Tribo air"
– To activate the function, the value is precisely adjusted with rotary controller 24
and is indicated in LED display 19
– Adjusting range: 0.1-4 m³/h
– Resolution: 0.05 m³/h
22 LED display: "Total air"
– Lights up yellow, when the setting "Total air" is selected
23 LED display: "Atomizing, ionizing and Tribo air"
– Lights up yellow, when the setting "Atomizing, ionizing and Tribo air" is selected
ORDER NUMBER DOC2326960
PEM-X1 CG
30

Hide quick links:

Advertisement

Table of Contents