ASSEMBLY AND COMMISSIONING

6.1

TRAINING OF ASSEMBLY/COMMISSIONING PERSONNEL

The assembly and commissioning personnel must have the technical skills to safely
commission the device.
When assembling, commissioning and carrying out all work, read and follow the operating
manuals and safety regulations for the additionally required system components.
A skilled person must check to ensure that the device is in a reliable state after it is assembled
and commissioned.
6.2

STORAGE CONDITIONS

Until the point of assembly, the device must be stored in a dry location, free from vibrations
and with a minimum of dust. The device must be stored in closed rooms.
The air temperature at the storage location must be between -20 °C and +60 °C
(-4 °F and +140 °F).
The relative air humidity at the storage location must be between 10 and 95%
(without condensation).
6.3

INSTALLATION CONDITIONS

The air temperature at the installation site must be in a range between 0 °C and 40 °C; 32 °F
and 104 °F.
The relative air humidity at the installation site must be between 10 and 95%
(without condensation).
6.4

PREPARING THE CUP GUN

6.4.1 SELECTION OF A SUITABLE NOZZLE SYSTEM

The process of changing from the flat jet nozzle to the deflector cone is described in
chapter 8.7.
You will find the article numbers of the different nozzles in Chapter 12.
Application overview
Complex part geometries
– Flat work pieces
(reduced picture frame)
– Profile
– Undercuts
– Wire goods
– Grid designs
– Small components
ORDER NUMBER DOC2326960
Powder cloud
Widely spread flat powder cloud
Round powder cloud
Size of the powder cloud is
dependent on the deflector plate
diameter
PEM-X1 CG
Nozzle
Flat jet nozzle
P_01664
Deflector cone
P_01665