Chapter 12 Safety And Regulatory Information; Environmental, Safety, And Electrical Information - HP Aruba 6400 Series Installation And Getting Started Manual

Table of Contents

Advertisement

Environmental, safety, and electrical information

Table 15: Environmental specifications for 6400 switch models
Item
Operating Temperature:
Non-Operating Temperature:
Operating Relative Humidity:
Non-Operating Storage Relative Humidity:
Maximum Operating Altitude:
Maximum Non-Operating Altitude:
Table 16: Safety and regulatory information for Aruba 6400 switches
Topic
Safety-EU:
Safety-World Wide:

Chapter 12 Safety and regulatory information

Range
0° to +45°C (+32°F to +113°F) up to 5000 ft; derate -1° C for
every 1000 ft from 5000 ft to 10000 ft
-40° to +70°C (-40°F to +158°F) up to 15000 ft
15% to 95% at 45°C (104°F) non-condensing
15% to 95% @ 65°C (149°F) non-condensing
3.05 km (10,000 ft) above sea level
4.57 km (15000 ft) above sea level
Range
EN 60950-1:2006 +A11:2009 +A1:2010
+A12:2011 +A2:2013
EN62368-1, Ed.2
IEC 60950-1:2005 Ed.2; Am 1:2009+A2:2013
IEC62368-1, Ed. 2
IEC 60825-1:2014 (Applies to products with lasers)
Safety and regulatory information
NOTE: Above 5,000 ft, operating temperature is
derated by 1°C (1.8°F) per 305m (1000 ft).
Chapter 12
Table Continued
99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aruba 6405Aruba 6410

Table of Contents