Safety And Regulatory Information For 1850 Office Connect Switch Series - HP OfficeConnect 1850 6XGT 2XGT/SFP Series Quick Setup Manual And Safety/Regulatory Information

Officeconnect 1850 series
Table of Contents

Advertisement

1.
Environment with high concentration of dust.
2.
Environment with high concentration of salt in the air surrounding and cooling the product.
3.
Environment with high concentration of corrosive gases such as Sulfur Dioxide(SO2),
Hydrogen Sulfide(H2S), Chlorine(CL2), and Ammonia(NH3), etc.
Please reference the Software End User License Agreement and Hardware Limited Warranty
for Hewlett Packard Enterprise Networking for more details. www.hpe.com/networking/warranty.

Safety and Regulatory Information for 1850 Office Connect Switch Series

For important safety, environmental, and regulatory information, see Safety and Compliance
Information for Server, Storage, Power, Networking, and Rack Products, available at http://
www.hpe.com/support/Safety-Compliance-EnterpriseProducts.
Electrical: Non-PoE
HPE 1850-8XG Switch
(JL169A)
HPE 1850-24G Switch
(JL170A)
HPE 1850-48G Switch
(JL171A)
Electrical: PoE+
HPE 1850-24G-PoE+
(185W) Switch (JL172A)
HPE 1850-48G-PoE+
(370W) Switch (JL173A)
Environmental:
Operating Temperature:
Operating relative humidity:
Non-operating/storage
temperature:
Non-operating/storage
relative humidity:
Maximum Operating
Maximum non-operating
Airflow direction
Safety — EU
Safety — World-Wide
Safety — North American
Safety:
10
HPE OfficeConnect 1850 Switch Series Quick Setup Guide and Safety/Regulatory Information
Rated AC voltage
100-127 V
nl
200–240 V
100-127 V
nl
200–240 V
100-127 V
nl
200–240 V
Rated AC voltage
100-127 V
nl
200–240 V
100-127 V
nl
200–240 V
1850-8XG, 1850-24G, 1 4.82A 850-48G, 1850-24G-PoE+, 1850-48G-PoE+ Switches
0°C to 40°C (32°F to 104°F)
15% to 95% at 40°C (104°F), non-condensing
-40°C to 70°C (-40°F to 158°F)
15% to 95% at 65°C (149°F), non-condensing
3.0 km (10,000 ft)
Altitude:
4.57 km (15,000 ft)
altitude
Side-to-side
EN 60950–1:2006 +A11:2009 +A1:2010 +A12:2011+A2:2013
IEC60950–1:2005 +A1:2009 +A2:2013
CSA 22.2 No 60950–1–7 2nd; UL60950–1 2nd
Lasers:
EN 60825-1:2007/IEC 60825-1:2007, Class 1
Maximum AC Current
0.9 A
nl
0.5 A
0.6 A
nl
0.4 A
1.0 A
nl
0.6 A
Maximum AC
PoE+ available
Current
power
2.5 A
185 W
nl
1.3 A
5.0 A
370 W
nl
2.4 A
AC power frequency
range
50/60 Hz
50/60 Hz
50/60 Hz
AC power
frequency range
50/60 Hz
50/60 Hz