BECKHOFF
8.3.3

Technical data for cables

Further information on the chemical, mechanical and electrical characteristics of the cables can be
obtained from out customer service .
Observe the restrictions in the chapter "Conductor cross-sections" on page 20.
To operate the amplifier with the max. permitted cable length, you must use cable
material which meets the requirements on the capacity given below.
Insulation material
Sheathing
Core insulation
Capacitance
Motor cable
Feedback cable
AX2040/2070 Product Manual
06/2007
PUR (polyurethane, code 11Y)
PETP (polyesteraphtalate, code 12Y)
£ 4mm² : less than 150 pF /m
>4mm² : less than 250 pF/m
less than 120 pF/m