Technical description
6.9.3

Isolating transformers

If protection against indirect contact is absolutely essential despite a higher leakage current, or if an
alternative form of shock-hazard protection is sought, the AX2040/2070 can also be operated via an
isolating transformer.
A ground-leakage monitor can be used to monitor for short circuits.
We would advise you to keep the length of wiring between the transformer and the
servo amplifier as short as possible.
32
06/2007
AX2040/2070 Product Manual