Skyrc IMAX B6 V2 Instruction Manual page 10

Professional balance charger/discharger
Table of Contents

Advertisement

NiMH/NiCd Battery Program
NiMH/NiCd Discharge Mode:
After selecting the correct battery type, use
NiMH DISCHARGE
the INC or DEC button to select the
1.3A
CUT: 5.10V
"DISCHARGE" mode. Press the START
button and the amp rate value will begin
flashing. Use the INC or DEC buttons to
adjust the value to the desired discharge rate.
Press the START button again and the
voltage cut-off will begin to flash. Use the INC
or DEC button to adjust the value to the
desired rate.
Follow the instructions provided on your
NiMH
0.6A
5.43V
DCH
00:02:22
battery when setting the voltage cut-off. The
B6 V2 will stop discharging when the battery
has reached the preset voltage cut-off.
Press and hold the START button for 3
NiMH
0.6A
5.43V
mAh
seconds to start discharging. Once
DCH
00106
discharging has commenced, the charger will
display the following real-time information:
battery type, discharging current, battery
voltage, working mode, elapsed time and
discharged capacity.
When discharging is complete, the screen will
NiMH DONE
5.10V
read "DONE" and the charger will emit a
DISCHG
00:03:17
ringing sound.
The charger will display the elapsed time, end
voltage and the discharged capacity in mAh.
You can press the STOP button at any time
during the discharging process to stop the
discharge process.
· 18
NiMH/NiCd Re-Peak Mode:
Applicable to NiMH and NiCD batteries only, in re-peak mode the
charger can peak- charge the battery once, twice, or three times in a
row automatically. This process is good for confirming that the battery
is fully charged and for verifying how well the battery can accept a fast
charge. A five-minute cool-down delay occurs after each re-peak
charge.
IN RE-PEAK MODE, THE B6 V2 USES THE CHARGE AMPERAGE
AND VOLTAGE SETTINGS ENTERED IN CHARGE MODE.
NiMH RE-PEAK
2
START/ENTER
NiMH
2.0A
6.28V
RPC
00:04:04
NiMH
2.0A
6.28V
RPC
00686mAh
B6 V2
B6 V2
NiMH/NiCd Battery Program
After selecting the correct battery type, use
the INC or DEC button to select the "RE-
PEAK" mode. Press the START button and
the Re-peak cycle number 1 begins to flash
on the screen. Use the INC or DEC button to
scroll through the cycle count and set a
number between 1 and 3.
Press and hold the START button for 3
seconds to start the re-peak process.
Once the Re-Peak process has begun, the
charger will display the following real-time
information: battery type, charging current,
battery voltage, elapsed time and charged
capacity.
Once the Re-Peak process has completed,
the screen will read "DONE" and the charger
will emit a ringing sound. The charger will
display the charge/discharge capacity for
each cycle. Using the + and - buttons, you
can scroll through the history data of each
cycle.
19 ·

Advertisement

Table of Contents
loading

Table of Contents