7.4 Risk Assessment
Below, there is an outline of the different hazardous situations that may arise with our machines after leaving the factory, either
during the installation process, commissioning, maintenance, adjustment or disassembly. There is also reference to the risk
minimisation measures that must be taken during the aforementioned phases of the machine's life:
MECHANICAL HAZARDS
Risk
Structural
Stability
Shearing, Cut or
Severing
Dragging and
entrapment
Impact and
crushing
Crushing
ELECTRICAL HAZARDS
Hazard
Direct or indirect
contact
Electrical energy
dispersal
Electromagnetic
compatibility
hazards
HAZARDS RELATED TO CONTROL AND SAFETY DEVICES
Hazard
Opening controls
Lack of power
Confinement
Dangerous
Risk Prevention Measures
Area
Machine area
Assess the suitability of the structure where the machine is going to be installed:
a levelled floor with sufficient load capacity, no obstacles in the transit area,
firm ground free of irregularities, etc.
Machine area
Attach the different machine parts in a stable way, using appropriate materials and strictly
adhering to the indications in this manual
Closing area
Do not use float glass to manufacture/repair the leaves of the machine.
Check that there are no burred or sharp edges on any of the different door parts.
Inside the
Do not manipulate the interior of the operator while it is in operation.
operator
Closing area
Adjust the closing force of the machine to a value appropriate for its operation.
Verify the correct operation of the safety photocell barriers.
Machine area
Exercise great caution when placing the leaf in its final location.
Dangerous
Risk Prevention Measures
Area
Inside the
Use components and electrical materials with CE marking.
operator
Connect the electrical connections, the mains connection, the earth connection and verify
all connections following the indications in the wiring and connections manual.
Ensure the continuity of the conductors by using cables with sharp edges.
Perform all maintenance and adjustment tasks by strictly adhering to the specifications in
this manual.
Operator
Follow the technical instructions applicable under the low-voltage electrotechnical
regulations.
Connect the electrical connections, the mains connection, the earth connection and verify
all connections following the indications in the wiring and connections manual.
Operator
Use components and electrical materials with CE marking.
Connect the electrical connections, the mains connection, the earth connection and verify
all connections following the indications in the assembly manual.
Dangerous
Risk Prevention Measures
Area
Door area
If manual controls are installed, place them correctly, protected from possible unauthorised
or malicious use.
Check and install the photocells following the instructions in the assembly, connection and
wiring manuals.
Door area
Check that the door operates safely again after the power supply has been interrupted.
Door area
Check that the panic break-out system works properly and ensure that the door opens after
power supply failure.
SWING OPERATOR - INSTALLATION MANUAL