Manusa VECTOR Installation Manual page 35

Table of Contents

Advertisement

D00619EN - v0
PAR
TYPE
10
5 -
ELECTRONIC
LOCK WITH AU-
TOMATIC RESET
11
6 -
-
ELECTRO
10
MAGNETIC
(
)
MAGLOCK
11
WITH DELAY
A
6.2
.
VALUE
See Fig. 32 - Electronic lock which, when powered, frees the leaf to move.
5
It resets by cutting power to the lock when the leaf opens more than 10°.
It requires a door jolt freeing device in order to make it easier to unlock
RANGE: 0÷9
the leaf.
[t=100÷1000 ms]
6
See Fig. 33 - A magnet that, when powered, keeps the door locked closed
and, when disconnected, frees it to move. It does not require a door jolt free-
RANGE: 0÷9
ing device. The magnet is powered again after the leaf is completely closed.
[t=200÷2000 ms]
Fig. 28.
Fig. 30.
Fig. 32.
SWING OPERATOR - INSTALLATION MANUAL
OPERATION
34
Fig. 29.
Fig. 31.
Fig. 33.