Manusa VECTOR Installation Manual page 31

Table of Contents

Advertisement

D00619EN - v0
ID
DESCRIPTION
19
MultiMaster address
20
Exclusion of opening safety
21
Double opening delay
22
Double closing delay
23
Input polarity SAFE OPEN
24
Input polarity SAFE CLOSE
25
Input polarity KEY
26
Input polarity START 1
27
Input polarity START 2
28
Input polarity AUX IN1
29
Input polarity AUX IN2
30
Output polarity AUX OUT 1
31
Output polarity AUX OUT 2
Level of force during LP proce-
32
dure
Percentage level of opening
33
angle reduction
34
Leaf installation
Opening speed for disabled per-
35
sons
36
Battery operation (only vectorS)
37
Configuration of the START 2
input
ST
Stop movement
TS
Test
Learning sensor (Procedure for
LS
automatically acquiring the su-
pervised sensors).
Default configuration of all the
Sd
parameters and points reset
Lp
Acquiring the leaf parameters
0 = Multimaster not managed
1÷ 15 = Unique address for MultiMaster connections
Angle of safety sensor exclusion during opening
RANGE: 0 ÷ 40% of the entire course
RANGE: 0 ÷ 100
Opening delay in 100ms units
(if 0 they are synchronised)
RANGE: 0 ÷ 100 Closing delay in 100ms units
(if 0 they are synchronised)
0 = NA (Normally Open)
1 = NC (Normally Closed)
0 = NA (Normally Open)
1 = NC (Normally Closed)
0 = NA (Normally Open)
1 = NC (Normally Closed)
0 = NA (Normally Open)
1 = NC (Normally Closed)
0 = NA (Normally Open)
1 = NC (Normally Closed)
0 = NA (Normally Open)
1 = NC (Normally Closed)
0 = NA (Normally Open)
1 = NC (Normally Closed)
0 = NA (Normally Open)
1 = NC (Normally Closed)
0 = NA (Normally Open)
1 = NC (Normally Closed)
RANGE: 5 ÷ 60 (0 = minimum force ÷ 9 = maximum force)
RANGE: 0÷50%
0 = mounted on lintel
1 = mounted on the leaf (reverse)
0 = Low Energy
1 = Speed as indicated in parameters 1 and 2
0 = standard (spring only)
1 = continuous operation
2 = panic breakout
0 = Operates as indicated on page 13
1 = Disabled persons opening: activate with switch B-fig.1- given in
logic settings 1
2 = Disabled persons opening: activate in all logic settings
0 = normal operation
1 = normal cycle
2 = quick cycle
1 - Select LS using keys [+] and [-]
2 - Press [ENT] to begin the procedure
3 - The display shows a value (SO; S1; S2; S3) that corresponds to
the detected configuration (sea section 'INSTALLING AND AC-
QUIRING THE SENSORS')
4 - press ENT to accept the detected configuration; ensure that it effectively
corresponds to the actual configuration of the sensors connected to the
operator, or ESC to reject the detected configuration.
1 - Select Sd using keys [+] and [-].
2 - Press [ENT].
3 - When the display shows [--], press [ENT] again for 5 seconds
to confirm.
4 - When the display stops showing [--], release the [ENT] key.
1 - Select Lp using keys [+] and [-].
2 - Press [ENT].
3 - When the display shows [--], press [ENT] again for 5 seconds
to confirm.
4 - When the display stops showing [--], release the [ENT] key.
30
SWING OPERATOR - INSTALLATION MANUAL
SETTING
DEFAULT
0
0
0
0
1
1
1
0
0
0
0
0
0
5
0
0
0
0w
0
0