D00619EN - v0
ID
DESCRIPTION
Return closing speed with spring
(VECTORM)
05
Wind protection function with the
door closed (VECTORM)
06
Crushing protection
07
Accelerations
08
Approach angle
09
Electronic lock control voltage
10
Electronic lock types
Electronic lock impulse duration
11
or opening delay
12
Electronic lock closing force
13
Individual/double mode
Activation of the electronic lock
14
according to the selected logic
settings
Configuration of the auxiliary
15
input AUX-IN 1
Configuration of the auxiliary
16
Input AUX-IN 2
Configuration of the
17
auxiliary output AUX-OUT 1
Configuration of the
18
auxiliary output AUX-OUT 2
RANGE: 1 ÷ 9
(1 = minimum speed, 9 = maximum speed)
RANGE: 0 ÷ 9
(0 = wind protection deactivated, 9 = maximum wind protection)
RANGE: 1 ÷ 9 both opening and closing
(1 = most sensitive ; 9 = least sensitive)
RANGE: 5 ÷ 30
(Regulating steps of 1) Modifies both accelerations and
decelerations
RANGE: 10 ÷ 40
[modifies both values (close equal to half (1/2) of the opening)]
0 = 12 VDC
1 = 24 VDC
0 = Not used
For electronic lock types that may be used, see section
'Management of Electronic Locks'
RANGE: 0 ÷ 9
The time depends on the type of electronic lock:
see section 'Management of Electronic Locks'
RANGE: 0 (min.) ÷ 9 (max.)
0 = Individual
1 = Double Master
2 = Double Slave
0 = Deactivated
1 = One Radar
2 = Two Radars
3 = One Radar and Two Radars
0 = Disabled persons opening
1 = Emergency opening
2 = Door interlocking with priority
3 = Door interlocking without priority
4 = Lock release feedback
5 = Lock release control
6 = Individual control with operational mode with Double
7 = Puts the door in stand-by (if it is active)
8 = Resets door stand-by
9 = Step-step (1 impulse opens, 1 impulse closes)
10 = Fire alarm
11 = Manual operation
12 = Door closed
0 = Disabled persons opening
1 = Emergency opening
2 = Door interlocking with priority
3 = Door interlocking without priority
4 = Lock release feedback
5 = Lock release control
6 = Individual control with operational mode with Double
7 = Puts the door in stand-by (if it is active)
8 = Resets door stand-by
9 = Step-step (1 impulse opens, 1 impulse closes)
10 = Fire alarm
11 = Manual operation
12 = Door closed
0 = Monitoring the sensors
1 = Interlocking
2 = Open-door state
3 = Closed-door state
4 = Malfunction
5 = Lock control repetition
0 = Monitoring the sensors
1 = Interlocking
2 = Open-door state
3 = Closed-door state
4 = Malfunction
5 = Lock control repetition
29
SWING OPERATOR - INSTALLATION MANUAL
SETTINGS
DEFAULT
5
0
5
30
20
0
0
2
5
0
3
0
1
0
1