5.15 Installing and Acquiring the Sensors

The operator is prepared to manage:
Safety sensors (see Fig. 21 A and B): they are mounted on the leaf and control the nearby area to detect possible
obstacles, and stop movement or invert it to prevent blows, crushing or other sources of danger;
Detection sensors (see Fig. 21 C and D): normally mounted on the wall, to detect when persons approach the door and
control the opening.
Connect the following sensors if they are present:
ID
17 = 0
Safety sensor supervised during closing (See Fig. 21 A)
30 = 1
17 = 0
Safety sensor supervised during opening (See Fig. 21 B)
30 = 1
Detection sensor (radar) on entry (See Fig. 21 D)
Detection sensor (radar) on exit (See Fig. 21 C)
If, when the device is put into operation, the configuration of the supervised safety sensors has not yet been memorised, the
display will show error E6. Exit this state by activating the automatic supervised sensor acquisition procedure (parameter LS,
see section 'Managing Operating Parameters of the Display'). During this procedure, the card waits until the sensors are
deactivated and checks the their supervision has been activated.
A
5.15
B
5.15
CARACTERÍSTICAS MECÁNICAS
SENSOR
Fig. 24.
Fig. 25.
26
SWING OPERATOR - INSTALLATION MANUAL
DIAGRAM
See Fig. 23
See Fig. 24
See Fig. 25
See Fig. 26