Installation; Type Of Arm That Can Be Installed; Installing The Operator - Manusa VECTOR Installation Manual

Table of Contents

Advertisement

D00619EN - v0

5 INSTALLATION

5.1 Type of Arm that Can Be Installed

RIGID ARM: (Used when the operator is installed on the same side that the door opens).
STANDARD ARTICULATED ARM: The standard articulated arm can be mounted to PUSH. (It is used when the
operator is installed on the opposite side from where the door opens).
LONG ARTICULATED ARM: The long articulated arm can be mounted to PUSH. (It is used when the operator is
installed on the opposite side from where the door opens, where the door jamb is particularly deep).
WARNING: For a correct installation, consult the corresponding sections for 'Installing the Arms'.

5.2 Installing the Operator

To attach the operator, follow the steps below (Fig. 3):
Remove the main cover (B)
Disconnect all connections (key-pad, switch, transformer, motor) on the electronic card ©, unscrew the 2 screws and
remove the card ©. The two screws remain in place between the circuit board and the lower base
Unscrew and remove the 2 transformer fixing screws (G)
Unscrew and remove the 4 gear motor group fixing screws (D)
Remove the two end covers (E) and (F)
Attach the main extruded profile (A) to the wall following the instructions in the following sections, depending on the type
of arm used
Assemble all the components, with the exception of the end covers and the main cover, following the steps above in
reverse order.
When reassembling, to aid installation, tighten first the two lower gear motor group fixing screws, then support it on them,
tighten the other two, such that the gear motor shaft end is perpendicular to the upper profile of the leaf