Arm-Type Selection; Connecting The Controls/Inputs - Manusa VECTOR Installation Manual

Table of Contents

Advertisement

D00619EN - v0

5.12 Arm-Type Selection

Rigid arm (Left or right-opening leaf)
→ Configure the right program switch as shown in Fig. 11.
Articulated arm (Left and right-opening leaf)
→ Configure the left program switch as shown in Fig. 11.

5.13 Connecting the Controls/Inputs

SIGNAL
DEFAULT
KEY
NC
START 1
NO
START 2
NO
SAFE
NC
OPEN
SAFE
NC
CLOSE
COM
AUX IN 1
NO
AUX IN 2
*
DESCRIPTION
Lock signal. Closing
devices, such as the
electronic
key,
the
key program switch,
the transponder, etc.,
may be connected.
Opening signal. De-
vices can be connect-
ed for leaf opening
control.
Opening signal. De-
vices can be connect-
ed for leaf opening
control.
Opening safety sig-
nal: other protective
sensors can be con-
nected for additional
safety
during
the
opening phases of
the leaves.
Closing safety signal:
other protective sen-
sors can be connect-
ed for additional safe-
ty during the closing
phases of the leaf.
Common in electrical signals.
Signal that, depending on the settings, may have the following configurations:
0 - Disabled persons
opening
1 - Emergency
opening
2 - Door interlocking
with priority
3 - Door interlocking
without priority
4 - Lock release
feedback
5 - Lock release
control
6 - Individual control
with Double operation
mode
If the signal starts, the central unit controls the full leaf closing (from any
position). Until this signal is no longer received, the door will remain
closed and will not detect any external peripheral devices (including the
multi-logic program switches).
The signal should be shorted with COM if there are no devices connected.
The end of this signal causes the leaves to open. This signal is controlled
only with 2 radars logic setting.
The end of this signal causes the leaves to open. This signal is controlled
both with 2 radars logic setting and 1 radar logic setting.
If the door is in the opening phase and the contact is open, the central unit
will order the manoeuvre to immediately stop. Opening will continue only
after this signal has been deactivated.
The signal should be shorted with COM if there are no devices connected.
If the door is in the closing phase and the contact is open, the central unit
will immediately order the reverse movement. Closing will start again only
once the contact is closed again.
The signal should be shorted with COM if there are no devices (internal or
external) connected.
Opening control for disabled persons. LOW ENERGY open and close with
a minimum 5 second pause.
It controls door opening regardless of the existing logic settings, overriding
as priority even the KEY input.
It identifies the device used in the interlocking logic setting, with the door's
as priority.
It identifies the device used in the interlocking logic setting, with the door's
without priority
Control used to indicate that the lock is released. Connect the micro-
switch or the contact to detect the state of the released lock.
Control allowing the lock to be released manually, without controlling the
opening of the leaf.
Signal that allows the device to be controlled as if it were individual when
it operates with a double leaf.
24
SWING OPERATOR - INSTALLATION MANUAL
FUNCTION