WARNING: Attach the door's leaf-joining point to the arm correctly, using reinforcements where necessary.
•
Turn the nut (Fig. 8 part A) to preload the spring, until the plate ends (Fig. 8 part. B) coincide with the line indicating the
start point of the EN4 range (level L=0).
•
Place the arm connection (Fig. 9 part A) on the operator output axis, so that the first part of the arm is perpendicular to
the operator mounting surface (Fig. 17).
•
Tighten the screw (Fig. 9 part C) so that the arm connection remains anchored to the operator output axis.
•
Screw in the three M8 x 16 hexagon button-head screws (Fig. 16 part B) without tightening so that the parts that make
up the articulated arm are joined together.
•
With the leaf close, turn the part of the arm where the connection is to slightly compress the spring (see fig. 17).
•
Fix the adjustment by firmly tightening the three M8 x 16 fixing screws (Fig. 16 part. B).
•
Adjust the spring [see section 'Spring Adjustment'].
E
5.5
F
5.5
WARNING: After installing the rigid arm and the guide, ALWAYS check that the Switch position is to the
left, as in Fig. 11.
Fig. 17.
Fig. 11.
20