Step 3: Ground the ACX5096 Router

IN THIS SECTION

Tools Required to Ground the ACX5096 Router | 7

Connect the Grounding Cable | 8
You must ground the router before connecting power.
Tools Required to Ground the ACX5096 Router
Ensure that you have the following parts and tools available:
Protective earthing terminal bracket—This bracket attaches to the ACX5096 router chassis through the
front mounting bracket on the left, providing a protective earthing terminal for the router.
Grounding cable for your ACX5096 router—The grounding cable must be 14 AWG (2 mm²), minimum
90° C wire, or as permitted by the local code.
Grounding lug for your grounding cable—The grounding lug required is a Panduit LCD10-10A-L or
equivalent.
Two M4 hex nuts with integrated washers—Two nuts and washers are used to secure the grounding lug
to the grounding lug bracket protective earthing terminal. Four nuts are provided in the accessory kit.
7-mm wrench or socket with driver to attach the two nuts.