PeakTech 1210 Operation Manual page 137

Digital oscilloscope with colour display
Hide thumbs Also See for 1210:
Table of Contents

Advertisement

Available languages

Available languages

Carry out the following operation steps for the time cursor measurement of the channel CH1:
1. Press "CURSOR" and recall the CURS MEAS menu.
2. Press the F1 menu selection button and choose Time for Type, with two purple dotted lines displayed
along the vertical direction of the screen, which indicating Cursor 1 and Cursor 2.
3. Press the F2 menu selection button and choose CH1 for Source.
Adjust the positions of CURSOR1 and CURSOR2 according to the measured wave form, with the cycle
4.
and frequency of Cursor1 and Cursor 2 displayed in the increment window. The current position of
Cursor1 is displayed in the Cursor1 window and that of Cursor2 is displayed in the Cursor2 window (see
Fig. 57).
Fig. 57 Wave Form of Cursor Measurement
136

Advertisement

Table of Contents
loading

This manual is also suitable for:

1215

Table of Contents