the use of fresh air supply set is also recommended.
Insufficient air supply can cause poor draught and
thereby low combustion efficiency and the problems this
entails: soot stains on the glass, inefficient utilisation of
the wood and a soot deposits in the chimney.
Warning!
Keep combustion and convection air inlet free
from blockage.
Warrning! Extractor fans when operating
in the same room or space as the appliance
may cause problem.
Distance illustration (FIG 1 - 1F)
*The illustration indicates the approximate centre height
of the recess for the flue. Consider possible inclination
of the flue prior to making perforating the chimney.
Distortions in floors and walls may also influence the
height, dry stack therefore the fireplace for accurate
height and positioning of the flue/chimney connection. If
a fresh air supply set (accessory) is connected through
the floor, mark where the hole should be.
Attention! Since the inner core is composed of
many layers the connection height may vary by up
to a few centimeters from installation to installation.
Safety distances (FIG 2 - 2A)
Ensure that the safety distances are complied with.
IMPORTANT! Drying Process
The fireplace contains a lot of moisture when it is
new and no fire has been made before. This mois-
ture must be dried out before the fireplace can with-
stand the combustion rate given below.
To extract the moisture, follow this procedure:
1. Ensure that the air vent control just below the door is
completely open
2. Ensure that the damper is in ignition mode.
3. Make a small fire with 0.5-1 kg of kindling wood
4. Set the damper in operating mode, once the flames
have taken proper hold of the wood, this will ensure
that the hot smoke circulates the ducts.
Attention! Let the air vent and damper remain open
until the fire is burnt out.
This procedure is repeated twice more, with a 24 hrs
gap between each time.
Attention! Failure to follow the guidelines for drying
can cause the elements to crack.
The air vent control is turned to the right to increase
-
the air supply to Salzburg M II

Combustion pace

An accumulating fireplace is designed to absorb thermal
energy during a relatively short period of relatively
intense heat. When the period of intensive combustion
is completed, the product will deliver the accumulated
heat over a longer period of time.
Attention! Combustion beyond the recommended
pace (see table with Technical Information) will
result in a higher surface temperatures, which
can lead to discoloration of the paint. It can also
result in higher than intended temperatures against
combustible walls.
Follow the values in the table to find the correct load
size and what loading interval is right for your product.
When the last load has passed into the ember phase
with few embers left, the air vent and damper is closed
to prevent heat escaping through the chimney.
Remember to open the flue damper before making a fire
in the fireplace.
The ignition mode should only be open during when
necessary for short periods (10-15 minutes) at the time
a fire is lit, and at new loads, in order to prevent smoke
or ash escaping into the room. Persistent combustion
with an open ignition mode can result in exceeding the
maximum allowed chimney temperature.
Due to the length of the smoke gas ducts, the
fireplace is heated up somewhat unevenly. After
lighting a fire, the front above the door and one of
the sides will heat up first. The heat will then be
evened out after a few hours of burning and when
all the ducts have been warmed up.

6. Assembly

Attention! It is very important that installation in-
structions are read carefully and followed closely in
order to ensure optimal functioning of the product.