Roland CAMM-1 Pro PNC- 1410 Service Notes page 37

Table of Contents

Advertisement

Enter the Service Mode by turning on the power while
8
pressing [
], [
] and [
[
], [
] keys, and push [ENTER] key.
Push the [ENTER] key.
9
- Pen will be in DOWN position.
Adjust VR1 on the MAIN BOARD ASS'Y so that the pressure
10
would be 26 ~ 30 gf when pen tip leaves the BED.
Push the [ENTER] key.
11
- Pen will be in UP position.
] keys. Select "Force" with
Sensor
DRAM
EEROM
Ageing
Force
Key
Calib.
Landing
ENTER
Force
adjust
[
up ]
20g
Force
adjust
[
up ]
Force
adjust
[ down ]
ST-012
BED
MAIN BOARD ASS'Y
Force
adjust
[ down ]
Force
adjust
[
up ]
4 Adjustment
Press the [right] key
four times.
4
20g
ENTER
20g
PEN
CARRIAGE
VR1
20g
ENTER
20g
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Camm-1 pro pnc-1210Camm-1 pro pnc-1860Camm-1 proPnc-1860Pnc-1410Pnc-1210

Table of Contents