Page 1
If you find any misprint or error, please inform us. • Roland DG Corp. assumes no responsibility for any direct or indirect loss or damage which may occur through use of this product, regardless of any failure to perform on the part of this product.
Page 2
The illustrations appearing in this manual depict the SX-15. The SX-12 and SX-8 may differ from the product shown. For information about how to use the included Dr. STIKA PLUS program, see the PDF manual for Dr. STIKA PLUS on the Roland Software Package CD-ROM, or refer to the program's help screens.
If You're Using Windows 2000 ........................ 3-5 Cutting Range ............................3-6 Changing the Loaded Material Width on the SX-15 .................. 3-7 Change the Loadable Material Width to 280 to 305 mm (11 to 12 in.) ..........3-7 Returning the Loadable Material Width to 360 to 381 mm (14-1/8 to 15 in.) .......... 3-9 Correcting the Slant of Loaded Material ....................
Page 4
Care and Maintenance ..........................4-1 Cleaning the Blade Tip ........................... 4-1 Cleaning the Blade Holder ........................4-1 Cleaning the Machine ..........................4-1 Replacing the Blade Protector ........................ 4-2 What to do if............................... 4-3 Specifications ............................. 4-6 Output from Roland CutChoice™ ......................... 4-7...
Use with other than the included power cord may lead to fire or electrocution. Doing so may result in fire or electrocution. Immediately unplug the power-cord plug from the electrical outlet, and contact your authorized Roland DG Corp. dealer or service center.
Page 6
Do not use with a damaged AC Do not damage or modify the adapter, power cord, or power-cord electrical power cord, subject it to plug, or with a loose electrical outlet. excessive bending, twisting, pulling, Doing so may lead binding, or pinching, or place any to fire, electrical object or weight on it.
About the Labels Affixed to the Unit These labels are affixed to the body of this product. The following figure describes the location and content of these messages. Rating label Use a rated power supply. Model name In addition to the symbols, the symbols shown below are also used.
Application tape for test cuts : 1 Replacement blade protector : 1 Roland Software Package CD-ROM: 1 *The configuration differs according to the model. Roland CutChoice CD-ROM : 1 SX-15/12/8 User's Manual : 1...
* There is packing material under the blade holder. Remove the packing material before you start cutting. * * The SX-15 has sheet adjustment levers on the left and right, and the SX-12 has a sheet adjustment lever only on the right.
Use within a temperature range of 5 to 40 C (41 to 104 F) and within a humidity range of 35 to 80%. Make sure the power to the computer and the SX-15/12/8 is switched off before attempting to connect the cables.
Attach the included ferrite core at the location on the connection cable shown in the figure. 20 to 30 mm (13/16 to 1-3/16 in.) 20 to 30 mm from the connector on the SX-15/12/8 (13/16 to 1-3/16 in.) *Secure in place with cable ties.
Part 1 Introduction Installing and Setting Up the Software Operating Environment for Dr. STIKA PLUS - Microsoft ® Windows ® 95, Windows 98, Windows Me, Windows NT ® 4.0, or Windows 2000 operating system ® - The minimum required CPU for the operating system (Pentium or higher recommended) - The minimum amount of required RAM for the operating system (32 Mbytes or more recommended) - 5 Mbytes or more of free hard disk space for installation...
Log on to Windows as a member of the “Administrators” or “Power Users” group. For more information about groups, refer to the documentation for Windows. Make sure the power to the SX-15/12/8 is turned off. Switch on the computer and start Windows.
Page 14
Click [Finish], and finish installing the Dr.STIKA PLUS. Viewing the PDF manual for Dr. STIKA PLUS. The CD-ROM included with the SX-15/12/8 contains the "Dr. STIKA PLUS User's Manual" as a PDF file. For [Dr. STIKA PLUS], click [Read the User's Manual].
Page 15
Check the values, click [Close], and finish installing the driver. At the Setup screen, click to close the window. Remove the CD-ROM from the CD-ROM drive. *If the SX-15/12/8 does not operate when you send data from the program, take a look at "4.2 What to do if..".
Part 2 Performing Cutting Part 2 Performing Cutting Load the Material Place the material against the pinch rollers. Pinch rollers Load the material as shown in the figure, so that it does not come loose during cutting. Make sure the two sides of the material are even. Turn the sheet feed knob to align the forward edge of the material with the back of the blade protector.
Cut off from the roll a length of material equal to the require length for cutting plus a margin of 30 mm. (43-1/4 in.) The SX-15/12/8 can be loaded with material up to 1100 mm (43-1/4 in.) in length. However, the cutting area is only up to 1,000 mm (39-5/16 in.).
"3 Mastering the SX" or the help for Dr. STIKA PLUS and the driver. SALE Starting the Software Click [Start], and point to [Program]. Then point to [Roland Dr. STIKA PLUS] and click [Dr. STIKA PLUS]. The opening screen appears and Dr. STIKA PLUS starts.
Page 19
Part 2 Performing Cutting Using Help When creating data, if you're unsure about how to proceed, follow the steps below to view the help screens. Also, when carrying out an operation for the first time, you can display help on your computer to guide you as you proceed.
[Roland SX-12]. For the SX-8, select [Roland SX- 8]. Then click [Properties]. The [Properties] dialog box appears. * The screen at right is shown when [Roland SX-15] has been selected. Set the cutting range. If you are using the included material, make sure the cutting range is set to the following values.
Page 21
For more information about groups, refer to the documentation for Windows. From the [File] menu, click [Print Setup]. The [Print Setup] dialog box appears. For the SX-15, select [Roland SX-15]. For the SX-12, select [Roland SX-12]. For the SX-8, select [Roland SX- 8]. Then click [Properties].
Page 22
For more information about groups, refer to the documentation for Windows. From the [File] menu, click [Print Setup]. The [Print Setup] dialog box appears. For the SX-15, select [Roland SX-15]. For the SX-12, select [Roland SX-12]. For the SX-8, select [Roland SX- 8]. Then click [Properties].
Page 23
Set the cutting range. If you are using the included material, make sure the cutting range is set to the following values. SX-15 : 340 mm (13.38 in.) (width) 270 mm (10.63 in.) (length) SX-12 : 250 mm (9.84 in.) (width) 390 mm (15.35 in.) (length)
Part 2 Performing Cutting Manipulating Text and Shapes Entering and Saving Text The fonts that Dr. STIKA PLUS can use are limited to the TrueType fonts available for Windows. When selecting a font, non-TrueType fonts are not displayed. Refer to the help screens for more information about using fonts. The white area of the screen is the cutting range.
Page 25
Part 2 Performing Cutting Click . This encloses the "SALE" text in a rectangle so that only the area of the sheet around what is cut is peeled off. Drag -When you are cutting small text, you can make peeling easier by enclosing each single character in a square. -All object overlapping is contextual, with the most recently created objects arranged on top.
Page 26
Part 2 Performing Cutting Changing the Size You can freely enlarge or reduce the size by dragging up or down or to the left or right. Click Drag a text box with the mouse to change its size. Change the size to fit inside the white portion of the display.
Before performing cutting, make sure the SX-15/12/8 has been prepared as described in the sections "2.1 Load the Material" to "2.2 Creating Cutting Data" Close the front cover and press the [STANDBY] key.
If You Want to Stop Cutting Before It's Finished... Press the [STANDBY] key to switch off the power. Click [Start]. Click [Settings], then click [Printers]. For the SX-15, double-click the [Roland SX-15] icon. For the SX-12, double-click the [Roland SX-12] icon.For the SX-8, double-click the [Roland SX-8] icon.
Part 2 Performing Cutting Applying Cut Material When storing material that has been cut, be sure to cover it with application tape. This protects the material against dust. You can prevent the entry of dust inside the material by leaving an edge on the cut material at this time. Peel off excess portions of the sheet.
- Composition Vinyl chloride sheets - Thickness Sheet portion :0.1 mm (0.00394 in.) or less, including base paper of 0.3 mm (0.0118 in.) or less Switch off the power to the SX-15/12/8. Blade Holder Loosen the screw and pull out the blade holder.
Perform a cutting test to check the results of adjusting the amount of blade extension. With test cutting, the SX-15/12/8 actually cuts the material, allowing you to determine how well cutting is performed. Test cutting is performed when changing the type of material.
Part 3 Mastering the SX Changing the Blade If the material is still not cut attractively even after adjusting the blade extension and performing test cutting several times, the blade tip may be broken. Replace it with a new blade. Press the push-pin and remove the old blade.
Part 3 Mastering the SX 3.2 Setting the Tool Conditions If You're Using Windows 95/98/Me Start Dr. STIKA PLUS and display the [Properties] dialog box. For information on how to display the [Properties] dialog box, refer to "2.2 Setting the Cutting Range." Click the [Tools] tab.
Part 3 Mastering the SX If You're Using Windows 2000 Start Dr. STIKA PLUS and display the [Properties] dialog box. For information on how to display the [Properties] dialog box, refer to "2.2 Setting the Cutting Range." When using the included blade and material, there is no need to change the tool conditions.
• The front and the left and right side of the material are necessary margins to allow feed of the material by the pinch rollers. The cutting range is inside the dotted box. If You're Using the SX-15 If You're Using the SX-12/8 Pinch rollers...
3.4 Changing the Loaded Material Width on the SX-15 The SX-15 can also use material of a width for the SX-12 (280 to 305 mm (11 to 12 in.)) To change the loadable material width from 360 to 381 mm (14-1/8 to 15 n.) to 280 to 305 mm (11 to 12 in.), move the pinch-roller and change the driver setting for the cutting range.
Page 37
Load material of a width for the SX-12 (280 to 305 mm (11 to 12 in.)). Change the cutting-width setting for the SX-15 driver from 340 mm to 250 (13.38 to 9.84 in.) mm. For information about how to change the cutting width, see "2.2 Setting the Cutting Range and Tool Conditions."...
(right) Pinch-roller stopper Lower the right sheet adjustment lever. Load material of a width for the SX-15 (280 to 305 mm (11 to 12 in.)). Change the cutting-width setting for the SX-15 driver from 250 mm to 340 mm (9.84 to 13.38 in.).
If material is not loaded parallel with respect to the machine, the material may come loose during cutting. If you're using the SX-15/12, you can use the sheet adjustment lever to correct the slant of material without removing the material from the machine.
You can import files and created data in Windows bitmap format (having the file extension *.bmp) into Dr. STIKA PLUS, perform outlining for the data, and cut the data on the SX-15/12/8. Depending on the image that is imported, some shapes that result may not be suitable for cutting. Keep the following conditions in mind as you create the data, then import it in Dr.
Part 3 Mastering the SX The data in the selected file is imported. Adjust the size and positioning. The size of the imported original image and the size of the data imported into Dr. STIKA PLUS are different. Refer to "2.2 Creating Cutting Data" and return the size of the object to the size you want. To Delete Unneeded Data When an imported object includes unneeded data, you can delete the unnecessary data using Dr.
You can import image data using a scanner. An image acquired with a scanner can be imported into Dr. STIKA PLUS and outlined for cutting with the SX-15/12/8. For detailed information, see the PDF manual or help screens for Dr. STIKA PLUS.
Part 3 Mastering the SX 3.7 Applying Large Material The larger the material is, the more difficult is it to apply while adjusting misalignment of the entire material, and the greater is the likelihood that air bubbles will get trapped between the material and the application surface. Applying detergent-containing water to the application surface makes it difficult for air bubbles to form and lets you move the position of the material as you affix it.
Part 4 User's Reference Part 4 User's Reference 4.1 Care and Maintenance When using a commercially available cutter knife for replacing the blade protector, do not place the hands anywhere along the path in the direction of blade movement. Doing so may result in injury. Cleaning the Blade Tip Material scraps or adhesive adhering to the blade tip can adversely affect cutting.
Slight scratching of the blade protector poses no problem for operation. However, the blade protector should be replaced if it becomes so severely damaged that cutting is adversely affected. Consult your vendor or your nearest Roland DG Corp. sales office for replacement of the blade protector. (Replacement of the blade protector is a charged procedure.) Switch off the power to the SX-15/12/8.
Is the printer port for Windows set to [ECP Printer Port]? If the computer and the SX-15/12/8 are connected by a parallel cable and there is no operation, check the printer port for Windows. If it is set to [ECP Printer Port], change it to [Printer Port]. For information on how to change the setting, contact the manufacturer of your computer.
Page 47
Part 4 User's Reference No squares or triangles ( ) are displayed around objects. Depending on the model of computer, squares and triangles ( ) for manipulating objects may not be displayed. The following two workarounds are available. They affect the entire operating environment of the computer. For information on how to change the settings, also see the help screens for Windows.
Page 48
Make sure the SX-15/12/8's driver is installed. If you connect the SX-15/12/8 to the computer and switch on the power to the SX while the SX driver is not installed on the computer, then when you start Windows, the message [Add Printer Wizard] appears.
AC adapter : 1, Power cord : 1, Ferrite cores : 2, Cable ties (For securing ferrite cores) :2, Blade holder/Blade : 1, Accessories Material for test cuts : 1, Application tape for test cuts : 1, Blade protect : 1, Roland Software Package CD-ROM: 1, Roland CutChoice CD-ROM:1, SX-15/12/8 User's Manual : 1 *When material having a length of 500 mm (19-5/8 in.) or more is used, then depending on the type of material, it may become misaligned.
Compatible programs : Adobe Illustrator 8.0/9.0 Viewing the User's Manual The user's manual for CutChoice is in PDF format. You can find it on the included Roland CutChoice CD-ROM. For detailed information about the features of CutChoice, see "Roland CutChoice.pdf."...
Page 51
Double-click the [Help] folder, then double-click the [English] folder to open it. Double-click "Roland CutChoice.pdf" and read the PDF manual. Output Results from CutChoice The data displayed in the CutChoice window is output on the SX-15/12/8 as shown in the figure. Roland CutChoice SX-15/12/8...
Page 52
AVIS Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. ROLAND DG CORPORATION 1-6-4 Shinmiyakoda, Hamamatsu-shi, Shizuoka-ken, JAPAN 431-2103 MODEL NAME : See the MODEL given on the rating plate.
Page 53
Roland may change the specifications of this Software or its material without notice. Roland shall not be liable for any damage that may caused by the use of the Software or by exercise of the right licensed by this agreement.
Need help?
Do you have a question about the Stika SX-15 and is the answer not in the manual?
Questions and answers