Danger through incorrectly dimensioned connection cables. The lifting station is only designed for operation
with the enclosed connection cables (or equivalent). If in doubt, consult the manufacturer / supplier.
Fit end sleeves (length 8 mm) to the ends of the cables
Lay the connecting cable safely from the system tank to the control unit (e.g. conduit pipe, cable duct)
Attach connecting cable to the terminal strip acc. to the
circuit diagram (next page). To do so, keep the relevant cable
terminal <3> pressed down against the spring pressure with a
suitable screwdriver until the end of the cable has been inserted
Attach strain relief fittings for all connecting cables
Connect battery plug to battery
Fit and fasten the housing cover,
tightening torque 1.2 Nm
Route the battery's cable (32) so that it does not cover
the LEDs or is clamped.
2017/11