Specifications
Measurement ranges
Output sensitivity
Output coupling
Accuracy (50/60Hz)
Frequency range
Max conductor size
Phase error (50/60Hz)
Minimum load
Linearity
Phase error
Conductor position sensitivity
Enclosure material
Safety
Power Supply
Operating Temperature
Operating Humidity
Dimension
Circuit box:
Flexible probe:
Cable length :
DC plug size :
Weight
actoolsupply.com
30A, 300A and 3000A, switch selectable
100mV/A on the 30A range
10mV/A on the 300A range
1mV/A on the 3000A range
AC coupled.
± 1% F.S. @ 23 ± 5°C (50/60Hz)
45 to 400 Hz.
Round: (177mm (7"), Oval: 216mm (8.5")
< ± 1°
100 K ohm for specified accuracy
±0.2% of reading from 10% to 100% of range
<±1.5° (50/60Hz)
± 2% F.S (conductor should be >25mm (1") from the probe
latch.
UL 94-V0 rated
IEC 1010, Category III 600V
8V± 1V (supplied from meter)
0°C to 50°C (32°F to 122°F)
Less than 80% RH
105 x 56.5 x 33 mm. (4.1 X 2.2 X 1.3"
600mm (23.6") (length), 14.5mm 0.57" (diameter)
3.4 meters (11.2 feet)
5.5 mm x 2.5 mm DIA.
480 g (1.06 LB)
4
actoolsupply.com
PQ-12-EU-EN V1.0 01/12