Alias Name Lists Page; Default Controls Page; Operation Settings Page - Sony MKS-R4020 Operating Instructions Manual

40 lcd button remote control panel, 16 rotary encoder remote control panel
Table of Contents

Advertisement

(Destination)
When a destination outside the range limit is selected,
sources 1 to 9999 are available for selection. In this
example, sources 0001 to 9999 are available for selection
for destination 3001.
The sources in the range containing the selected
destination are all enabled. In this example, sources 0001
to 3000 and 5001 to 8000 are available for selection for
destination 0001.
Adding a range
1
Click the [+] button.
2
Enter a source range and destination range in the
dialog.
3
Click the [Apply] button.
The specified settings are displayed in the list.
Selecting a row in the list displays a blue rectangle
covering the range available for selection.

Alias Name Lists Page

(Not supported on the MKS-E1620.)
Displays alias names sent from the system controller.
Select [Source] or [Destination] to display the list of alias
names for sources or destinations, respectively.

Default Controls Page

(Not supported on the MKS-E1620.)
Use to set the operation levels and default destination of
the unit.
Destination Settings
Control Destination
Specify the default control destination at startup.
(Source)
Configured area
Unconfigured area
17
Enable set control destination by page
If you configure a destination for each page and then
switch pages, this enables the function to change the
control destination to the configured destination for that
page.
Level Settings
Level Mode
Select level selection mode.
Single: Only one level can be selected. When a selection
button is pressed, only that level is enabled, and other
selected levels are deselected.
Multi: Multiple levels can be selected. The levels for a
pressed selection button are all selected. When a
selected button is pressed, the levels of that button are
deselected.
Use Level Type
Select the levels to use in the unit.
System: Use the levels specified by the system controller.
Local: Place a check mark in levels to set the levels used by
[Control Level].

Operation Settings Page

(Not supported on the MKS-E1620.)
Use to configure settings relating to the operation of the
remote control panel.
Mode Settings
Protect Mode
Set the operation mode when protection is applied. The
PROT lamp action is the same when either mode is
selected.
Protect: Crosspoint switching is disabled when protection
is applied.
Occupy: Crosspoint switching of protected remote control
panels only is enabled when protection is applied.
Salvo Protect
This selects the operation if salvo switching is executed
while destinations are protected.
Partial Protect: Switch only unprotected destinations.
Full Protect: Do not perform salvo switching if any one of
the destinations is protected. Select this mode if a
problem would occur if any one location does not
switch.
Button Link: Do not perform salvo switching if the PROT
lamp on the panel is lit.
Note
When [Protect Mode] is set to [Occupy] in the web menu to
enable local protection, salvo switching is not restricted by
the [Salvo Protect] setting.
BPS/MD Take Mode
Not supported on the MKS-R4020.
Preset Mode
Not supported on the MKS-R4020.
Enable Chop
Enable the chop function.