Overview Of Processing Units; Input Image; Measurement; Compensate Image - Omron Sysmac FH Series Operation Manual

Vision system, for sysmac studio
Hide thumbs Also See for Sysmac FH Series:
Table of Contents

Advertisement

4 Configuring Measurement Settings
4-1

Overview of Processing Units

This section provides an overview of the processing units that can be edited in the FH/FHV tools.
For details on each of the processing units, refer to Vision System FH/FHV Series Processing Item
Function Reference Manual (Cat. No. Z341).
4-1-1

Input Image

This is a processing unit for loading images from a camera.
The main setting items are as follows.
Group
Camera setting
Screen adjust
White balance
Calibration
HDR setting
Bright adjust setting
4-1-2

Measurement

This is a processing unit for inspection and measurement.
The main setting items are as follows.
Group
Model
Region setting
Detection point
Ref. setting
Measurement condition
Judgment condition
Output conditions
Color
4-1-3

Compensate Image

This is a processing unit for correcting images.
The main setting items are as follows.
Group
Filter setting
4 - 2
Sets the camera shooting conditions.
Sets the conditions related to the lighting and lens.
Sets the white balance in images loaded from the camera to correct its color
and to make the white parts appear as white.
Configures the settings for converting measurement results to the actual di-
mensions.
Sets the method for combining images in order to obtain it with a wide dynamic
range.
Sets how much the brightness of loaded images to be adjusted.
Allows you to register the parts you wish to inspect as models.
Sets the range for searching a model and the range for calculating the amount
of a certain feature.
Sets which parts of a model you wish to detect as the coordinates during

measurement.

Changes the measurement values that will be the reference registered during
model registration and region setting.
Sets the condition for performing measurement.
Sets the judgment condition for measurement values.
Sets the reflection condition for the coordinates or overall judgment output as
measurement results.
Sets the color information used for measurement.
Sets the filter conditions for image correction.
FH/FHV Series Vision System Operation Manual for Sysmac Studio (Z343-E1)