Performing Test Measurement; Measuring Camera Images - Omron Sysmac FH Series Operation Manual

Vision system, for sysmac studio
Hide thumbs Also See for Sysmac FH Series:
Table of Contents

Advertisement

6 Online Debugging
6-1

Performing Test Measurement

You can perform test measurement with the FH/FHV tools.
Select from the following three test measurement target images when connected with an online con-
nection.
Target Image
Camera image
File image
Logging image
6-1-1

Measuring Camera Images

To select a camera image, first click the camera image button (
Then select a camera image and click the Measure button.
Measure is provided in the following editing screens.
• Scene maintenance window
• Scene editing screen
• Processing unit editing screen
<Scene maintenance window>
<Scene editing screen>
6 - 2
Measurement Type
Single measure-
Measures a camera image.
ment
Continuous meas-
Continuously measures camera images.
urement
Single measure-
Allows you to select and measure a file image in the RAMDisk or
ment
the external memory, i.e. USB memory of the FH/FHV vision sen-
sor.
Continuous meas-
Continuously measures file images in the RAMDisk or external
urement
memory, i.e. USB memory of the FH/FHV vision sensor. Measure-
ment ends when measurement of the images within the same
folder finishes.
Single measure-
Allows you to select and measure a logging image in the FH/FHV
ment
vision sensor memory.
Continuous meas-
Continuously measures logging images in the FH/FHV vision sen-
urement
sor memory. Measurement ends when measurement of all logging
images finishes.
FH/FHV Series Vision System Operation Manual for Sysmac Studio (Z343-E1)
Description
) in the file selection section.

Advertisement

Table of Contents
loading

Table of Contents