What's in the box....................................6 About this user guide ..................................7 2 Parts, controls and connectors................................9 Front view......................................10 Rear view....................................... 11 Connector view ....................................11 2.3.1 MDSC-8255 LED version............................11 2.3.2 MDSC-8255 MNA version............................12 Connector pin assignments ................................12 2.4.1 DVI connector (DVI-D) ..............................12 2.4.2 USB type A connector..............................13...
Page 4
DVI output ..................................41 5.5.6 Operating hours ................................41 6 Important information....................................43 Safety information.....................................44 Environmental information................................47 Biological hazard and returns ..............................48 Maintenance ......................................49 6.4.1 Cleaning and disinfection ............................49 Regulatory compliance information ............................49 Explanation of symbols..................................50 Legal disclaimer....................................52 Technical specifications.................................53 K5902133 (451920612483)-02 MDSC-8255...
OR. Large screen UHD resolution display for referral imaging A futureproof choice for referral imaging in the OR, the MDSC-8255 can present information previously shown on four 27” monitors on one large screen, with all four images in full HD.
1.3 About this user guide Overview This manual provides support to the user during the installation, set up and utilization of the MDSC-8255 display. Depending on the specific version that has been purchased, some of the features and options described in this document may not apply to the display in user’s hands.
Multi-image selection key / Down key Image zoom key / Up key OSD menu key / Enter key Brightness decrease / Left key Brightness increase / Right key Stand-by key Power mode LED IR receiver (for remote control - future provision) K5902133 (451920612483)-02 MDSC-8255...
2.2 Rear view Overview Image 2-2 VESA mount screw holes (VESA 200 mm and up) Protective earth pin (for additional grounding) 2.3 Connector view 2.3.1 MDSC-8255 LED version Overview Image 2-3 SDI in SDI out HDMI2 2.0 in HDMI1 2.0 in +5 VDC –...
Parts, controls and connectors 2.3.2 MDSC-8255 MNA version Overview Main Image 2-4 Headphone out Microphone in Audio line out Audio line in USB 2.0 type A interface (4 x) USB 2.0 micro-B interface (for service use only) (2) Secondary SFP+ 10Gb optical Ethernet interface...
2.4.2 USB type A connector Overview Image 2-6 +5 VDC Data - Data + 2.4.3 USB type B connector Overview Image 2-7 Data - +5 VDC Data + 2.4.4 Micro-USB connector Overview Image 2-8 +5 VDC Data - Data + K5902133 (451920612483)-02 MDSC-8255...
Parts, controls and connectors Not connected DDC_SCL DDC_SDA DDC/CEC GND +5VDC POWER 2.4.7 DC out connector Overview Image 2-11 +5 VDC K5902133 (451920612483)-02 MDSC-8255...
Page 16
Parts, controls and connectors K5902133 (451920612483)-02 MDSC-8255...
To connect your MDSC-8255 to Barco's Nexxis OR system, connect the 10Gb Ethernet interface to your Nexxis switch. More info about Nexxis OR and how to configure the MDSC-8255 in your network is available in the dedicated user guides. Please visit www.barco.com...
WARNING: DisplayPort VESA DP 1.2 certified cables for 5.4 Gbps HBR2 are recommended. The DVI output must be enabled in the OSD menu (please refer to “DVI output”, page 41). 3.1.2 MDSC-8255 MNA version To connect the interfaces Connect one or more video source(s) to the corresponding video inputs of the display.
Main Image 3-3 CAUTION: The display must be earthed. Potential equalization When potential equalization between the display and other devices is required then connect the potential equalization pin (POAG) to the potential equalization terminal of the equipment. K5902133 (451920612483)-02 MDSC-8255...
Depending on the VESA plate thickness (T) and the thickness of possible washers (W), a different screw length (L) should be selected. Please respect the following rule to select an appropriate screw length: • = T + W + 8 mm • = T + W + 11 mm K5902133 (451920612483)-02 MDSC-8255...
Page 22
CAUTION: Use an arm that is in compliance with VESA requirements. CAUTION: The monitor VESA interface has been designed for a safety factor 6 (to support 6 times the monitor weight). In the medical system, use an arm with suitable safety factor (IEC60601–1). K5902133 (451920612483)-02 MDSC-8255...
(OSD Time-out). The OSD menu position can be adjusted in the OSD menu (OSD Hor. Pos. and OSD Vert. Pos.). 4.4 OSD menu navigation OSD menu structure explained Below is an example of the OSD menu structure: K5902133 (451920612483)-02 MDSC-8255...
The concept of shortkey functions is to present a selection of commonly used functions immediately available without the need to navigate through the OSD menu. The different available shortkey functions are: • Main source selection • Brightness adjustment K5902133 (451920612483)-02 MDSC-8255...
OSD lock window appear. The OSD menu can only be accessed after pressing a sequence of keys. Image 4-5 To lock/unlock the menu When the OSD lock window appears, press the following key sequence to unlock the OSD menu: K5902133 (451920612483)-02 MDSC-8255...
Page 27
Each time a key is pressed an asterisk is shown in the square boxes. After pressing the fourth key, if the sequence is correct, the OSD main menu is activated. After exit, the OSD menu will automatically lock again. K5902133 (451920612483)-02 MDSC-8255...
Advanced operation Not all features described in the chapter “Advanced operation” are available. The features not available in specific software versions are shown on OSD menu in light-grey. K5902133 (451920612483)-02 MDSC-8255...
Brightness level is adjusted by controlling the backlight illumination only. 5.1.3 Contrast To adjust the contrast level Bring up the OSD main menu. Navigate to the Picture menu. Enter the Contrast submenu. The command bar Contrast is highlighted. Set the contrast level as desired and confirm. K5902133 (451920612483)-02 MDSC-8255...
RGB primary calibration, according to the selected standard, is performed within the physical limitation of the LCD panel used. To select a color space preset Bring up the OSD main menu. Navigate to the Picture menu. Enter the Color Space submenu. K5902133 (451920612483)-02 MDSC-8255...
Set the black level as desired and confirm. 5.2.2 Latency About latency The video latency is defined as the delay between the time of a monitor input video transition to the corresponding light output transition on screen. K5902133 (451920612483)-02 MDSC-8255...
Enter the Image Size submenu. Select one of the available image sizes and confirm. 5.2.5 Image Flip About image flip This function allows you to flip the image on your display. The available options are: • Disabled (no image flip applied) K5902133 (451920612483)-02 MDSC-8255...
The available main sources for your display are: • • • DisplayPort • HDMI–1 (MDSC-8255 LED version only) • HDMI–2 (MDSC-8255 LED version only) • Nexxis (MDSC-8255 MNA version only) Available main source options may differ depending on display model.
Picture input”, page 37). If any of both functions are enabled then failover will be disabled and made unavailable. As soon as both functions are disabled again, failover will be enabled and made available again with the selected failover input. K5902133 (451920612483)-02 MDSC-8255...
The 2nd source keeps the same image size (Native/Aspect) as the Primary input Source. To select Picture and Picture input Bring up the OSD main menu. Navigate to the Input Select menu. Enter the PaP Input submenu. Select one of the available PaP sources (or NONE) and confirm. K5902133 (451920612483)-02 MDSC-8255...
Bottom right • Top right To select Picture in Picture position Bring up the OSD main menu. Navigate to the Input Select menu. Enter the PiP Position submenu. Select one of the available PiP positions and confirm. K5902133 (451920612483)-02 MDSC-8255...
• English • Français • Deutsch • Español • Italiano To select the language Bring up the OSD main menu. Navigate to the Configuration menu. Enter the Language submenu. Select one of the available languages and confirm. K5902133 (451920612483)-02 MDSC-8255...
The available profiles to save in your display are: • User 1 • User 2 • User 3 To save a profile Bring up the OSD main menu. Navigate to the Configuration menu. Enter the Save Profile submenu. K5902133 (451920612483)-02 MDSC-8255...
When the selected input(s) is (are) missing (main, 2nd and failover), this setting allows the display to switch off the backlight and enter a low power mode. As soon as the selected input(s) is (are) present again, the display K5902133 (451920612483)-02 MDSC-8255...
This information shows the operation hours of your display. To consult operating hours Bring up the OSD main menu. Navigate to the System menu. The operation hours of your display are shown at the bottom of the menu. K5902133 (451920612483)-02 MDSC-8255...
Power requirements: The equipment must be powered by the AC mains voltage. • The equipment should be installed near an easily accessible outlet. • The equipment is intended for continuous operation. Power cords: • Europe: H05VV-F or H05VVH2-F PVC cord with appropriate EU plug. K5902133 (451920612483)-02 MDSC-8255...
Page 45
Any external connection with other peripherals must follow the requirements of clause 16 of IEC60601-1 3rd ed. or Table BBB.201 of IEC 60601-1-1 for the medical electrical systems. Connection of PEMS by network/data coupling to other equipment (MDSC-8255 MNA version only) •...
Page 46
EMC: • IEC 60601-1-2 (4th Ed) • EN 55011 / CISPR11 (MDSC-8255: Class B) National Scandinavian Deviations for CL. 1.7.2 Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan" Norway: "Apparatet må tilkoples jordet stikkontakt" Sweden: "Apparaten skall anslutas till jordat uttag"...
Electronic Products ” (Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of toxic substances in Electronic Information Products”.
Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses (please refer to the photo) is based on the “General guidelines of environment-friendly use period of electronic information products” of Chinese Mainland.
The manufacturing country of the product is indicated on the product label (“Made in …”). Importers contact information To find your local importer, contact one of Barco’s regional offices via the contact information provided on our website (www.barco.com). FCC class B This device complies with Part 15 of the FCC Rules.
Indicates the device is approved according to the KC regulations Indicates the device is approved according to the BSMI regulations Indicates the device is approved according to the PSE regulations Indicates the device is approved according to the RCM regulations K5902133 (451920612483)-02 MDSC-8255...
Page 51
Indicates this device must not be thrown in the trash but must be recycled, according to the European WEEE (Waste Electrical and Electronic Equipment) directive Indicates Direct Current (DC) Indicates Alternating Current (AC) Stand-by Values for xx and yy can be found in the technical specifications paragraph. K5902133 (451920612483)-02 MDSC-8255...
Barco software products are the property of Barco. They are distributed under copyright by Barco NV or Barco Inc., for use only under the specific terms of a software license agreement between Barco NV or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized.
(Harmonized with Ed. 3.1) • IEC 60601-1: 2012 Edition 3.1 (Medical electrical equipment – Part 1: General requirements for basic safety and essential performance) • EN 60601-1: 2006 + A1:2013 (Medical electrical equipment - Part 1: General requirements for safety) K5902133 (451920612483)-02 MDSC-8255...
Need help?
Do you have a question about the MDSC-8255 and is the answer not in the manual?
Questions and answers