Control Panel Menu Structure - Blizzard Lighting Cyc Out User Manual

Table of Contents

Advertisement

Control Panel Menu Structure

ADDR
001-512
STAT
MAST INT
R INT
R DURA
R RATE
G INT
G DURA
G RATE
B INT
B DURA
B RATE
W INT
W DURA
W RATE
SET
NO DMX
CHMD
DIM
(dimming)
FAN
OUTPUT
INFO
SOFT
TEMP
POW
RESET YES/NO
WARNING: "MAX" OUTPUT MODE IS FOR USE IN STROBE/BLINDER APPLICA-
TIONS ONLY. CONTINUOUS USE OF THIS FIXTURE IN MAX MODE MAY CAUSE
PREMATURE FAILURE. FOR CYC/WASH USE, USE ONLY "CYC-HI" OR "CYC-LO"
MODES. SEE PAGE 13 FOR MORE INFORMATION.
Cyc Out™ User Manual Rev. D
To choose the DMX address
Master intensity (0% <--> 100%)
Red intensity (0% <--> 100%)
Red duration (0-255)
Red rate (0-255)
Green intensity (0% <--> 100%)
Green duration (0-255)
Green rate (0-255)
Blue intensity (0% <--> 100%)
Blue duration (0-255)
Blue rate (0-255)
White intensity (0% <--> 100%)
White duration (0-255)
White rate (0-255)
KEEP
Hold last signal upon DMX signal loss
BLACKOUT
Blackout upon DMX signal loss
STAT
Output current static value upon DMX signal loss
4CH
To run in 4-channel mode
5CH
To run in 5-channel mode
8CH
To run in 8-channel mode
10CH
To run in 10-channel mode
15CH
To run in 15-channel mode
16CH
To run in 16-channel mode
28CH
To run in 28-channel mode
LIN
Linear dimming curve
SQR
Square law curve
ISQR
Inverse square law curve
SCUR
S-curve
LIN.
Linear dimming curve (smooth)
SQR.
Square law curve (smooth)
ISQR.
Inverse square law curve (smooth)
SCUR.
S-curve (smooth)
ON
Keep fan on continually
SMART
Automatic temperature controlled fan cooling
MAX
Max output (100%) - Use with strobe only
CYC-HI
High output (70%) - high-output cyc/wash use
CYC-LOW
Low output (50%), low-output cyc/wash use
<ENTER>
Software version information
<ENTER>
LED board temperature in Celsius
<ENTER>
Current automated overheat protection level (100%/80%/50%)
Reset all default parameters, with the exception of ADDR.