Control Panel Menu Structure; Dmx Mode; Setting The Dmx Address; Setting The Dmx Channel Mode - Blizzard Lighting Motif Fresco Series Manual

Table of Contents

Advertisement

Control Panel Menu Structure

ADDRESS
001-512
STATIC
R
G
B
SHUT
SET
CAL
CHMD
DIM
(dimming)
LOCK
CUSTOM
CT01-CT10
AUTO
AT01-AT05
ATSP
CHS1
CHS2
CHS3
PROGRAM CHS1-CHS3
Custom
programs
1-3.
INFO
SOFT
POW
LOAD
ST L
PR L
SEND
YES/NO

DMX Mode

Allows the unit to be controlled by any universal DMX controller.

Setting the DMX Address:

1.) The default mode for the fixture is DMX, which appears as 001 on the LED readout. To
select a different DMX address, using the <MENU> button, select ADDRESS, then hit
<ENTER>. Use the <UP/DOWN> buttons to select the correct address, then hit <ENTER>
to confirm.

Setting the DMX Channel Mode:

1.) To select a DMX channel mode, press the <MENU> button, then use the <UP/DOWN>
buttons until the display reads SET and press the <ENTER> button. Then use the <UP/
DOWN> buttons until the display reaches CHMD, and press <ENTER>. Now press the <UP/
DOWN> buttons again to highlight your desired DMX channel mode, and press the <ENTER>
button to confirm.

Slave Mode:

1.) Daisy chain the fixtures DMX in/out, having the controller at the beginning of the line.
2.) There is nothing else to it! The first fixture in the DMX chain is the master fixture, and the
following fixtures will follow the master.
Motif Fresco™ User Manual Rev. B
To choose the DMX address
Red intensity (0% <--> 100%)
Green intensity (0% <--> 100%)
Blue intensity (0% <--> 100%)
Flash/strobe speed (0-255)
<ENTER>
To set global intensity levels of each color + USE: YES/NO
7CH
To run in 7-channel mode
5CH
To run in 5-channel mode
3CH
To run in 3-channel mode
LIN
Linear dimming curve
SQR
Square law curve
ISQR
Inverse square law curve
SCUR
S-curve
LIN.
Linear dimming curve (smooth)
SQR.
Square law curve (smooth)
ISQR.
Inverse square law curve (smooth)
SCUR.
S-curve (smooth)
<ENTER>
YES/NO, Unlock: <MENU>, <UP>, <DOWN>, <ENTER>, (3x)
<ENTER>
R/G/B adjustments for custom color banks 01-10
<ENTER>
Auto programs 1-5
<ENTER>
Auto Speed
<ENTER>
Custom program 1
<ENTER>
Custom program 2
<ENTER>
Custom program 3
SC01-SC25
R (0-255)
25 scenes
G (0-255)
for each
B (0-255)
custom
program.
<ENTER>
Software version information
<ENTER>
Current automated overheat protection level (100%/80%/50%)
Restore factory settings
Restore factory program settings
Sync settings between fixtures via DMX
Page 11
SHUT (strobe, 0-255)
AUTO (None, AT01-AT05)
ATSP (speed, 0-255)
TIME (duration, 0-255)
WAIT (before fade, 0-255)
USE (use scene, YES/NO)
(c) 2016 Blizzard Lighting, LLC

Advertisement

Table of Contents
loading

Table of Contents