4.2

Control Panel Indicators

The following is a description of the control panel indicators.
Service
Indicator
Pressure Indicator
The pressure indicator shows the current operating pressure of the
sprayer. It has three di erent indications: blinking yellow, solid
yellow, and solid green.
Blinking Yellow
When the pressure indicator is blinking yellow, the sprayer is
pressure indicator means:
If the pressure indicator begins blinking yellow when
i
the pressure control knob is set at a higher pressure
and the relief valve is in the SPRAY position, either
the spray tip is worn or the sprayer is in need of
service/repair.
Solid Yellow
When the pressure indicator is solid yellow, the sprayer is operating
pressure indicator means:
GB
Solid Green
When the pressure indicator is solid green, the sprayer is operating
pressure indicator means:
4
Service Indicator
The Service indicator is on when the motor is commanded to run.
This indicator is used by service centers to troubleshoot motor
problems.
4.3
Pressure
Indicator
2. Black zone – no pressure generation
3. Blue zone – pulsating pressure for cleaning
4.4
Attention
Before connecting the unit to the mains supply, ensure that the line
i
pressure setting
pressure is set so that it starts at solid green, it indicates one of
the following:
a. Tip Wear Indicator
pressure the solid yellow appears. This means the tip is
worn and needs to be replaced.
b. Tip Too Large — when a tip that is too large for the sprayer
is put in the gun, the pressure indicator will turn from solid
green to solid yellow.
c. Fluid Section Wear — if a solid yellow pressure indicator
appears when using a new tip and the pressure is set at
piston, stuck valve, etc...).
Pressure control knob settings (Fig. 6)
1
2
3

Connection to the mains network

The unit must be connected to an appropriately-
grounded safety outlet.
Wagner's accessories program also includes a mobile
operator protection device for the electronic supply,
which can also be used with other electronical
equipment.
Starting operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prospray 3.31055800505580370558038

Table of Contents